3M 747 manual Overview, Product Outline

Page 6

1.0Overview

1.1Product Outline

WARNING

To reduce the risks associated with an explosion hazard, which, if not avoided, could result in death or serious injury:

Do not use in an explosive environment. 3MShoes and Wrist Strap Tester 747 is not designed to be intrinsically safe.

To reduce the risks associated with a medical device malfunction, which, if not avoided, could result in death or serious injury:

• Persons with heart pacemaker devices should never use this Shoes and Wrist Strap Tester 747.

The 3MShoes and Wrist Strap Tester 747 features:

(1)Evaluation of Electrostate Protection Provided by ESD Shoes and Wrist Straps A single device measures the electrical resistance of a body while wearing ESD shoes and wrist straps.

(2)Quick Measurements

Displays measures value and test results, and makes the results available for output within one second after starting measurement.

(3)Power Saver Function

Conservers power by automatically turning off (or entering stand-by state during AC operation) ten second after completing a measurement.

(4)Test Result Display and Output

Displays OK, HIGH, or LOW test results on panel LEDs. Testing threshold resistance values are set by simple switch selections. Results are also available at an open-collector output terminal. Refer to Section 4.1, “Open Collector Output.”

(5)RS-232C Interface

Test results are available to an external PC through a serial (RS-232C) interface. Refer to section 4.2, “RS-232C Communications.”

5

Image 6
Contents 3M Shoes and Wrist Strap Tester Table of Contents Introduction InspectionExplanation of Safety Label Signal Words & Symbols Intended UsePage Overview Product OutlineLCD Indicators Side Panels Back SidePreparation Before Testing Connecting the ESD Shoe Testing PlateShoes Power Preparation Installing and Replacing the Batteries Power Saver Function Turning Power On and OffTurning Power Off AC Adapter ConnectionTesting Wall MountingALL setting is described in .1, Open Collector Output ESD Shoe Testing with the 3M Shoes and Wrist Strap TesterImportant Note Use single-conductor wrist straps only External Output Function Open Collector OutputTest Result Output Settings Test Result Output TerminalInternal Circuit Shoe and Wrist Strap ALL Setting Open-Collector OutputSpecifications RS-232C CommunicationsPC Connection Cable ConnectionsPC System Requirements Measurement Section Measurement Resistance Range 0 to 200.0 MΩMaintenance & Service Battery Replacement IndicatorError Messages LCD can display the following error messagesCleaning Testing ConsiderationsOperational Verification Test Testing Wrist Strap Ranges Equipment RequiredTest Set-Up Testing Wrist Low Limit Refer to Wrist Test Table Testing Wrist High Limits Refer to Wrist Test TableWrist Test Table Testing Shoe Ranges Testing Shoes Low Limits Refer to Shoes Test TableWeee Statement Regulatory InformationShoe Test Table CULus StatementFCC Electronic Solutions Division Static Control Products