3M 747 manual Table of Contents

Page 2

Table of Contents

 

Section

 

Page

Introduction

2

Inspection

2

Package Contents

2

Safety Information

3

Intended Use

3

Chapter 1.0

Overview

5

1.1

Product outline

5

1.2

Part Names and Functions

6

1.2.1

Front Panel

6

1.2.2

Side Panels

7

1.2.3

Back Side

7

Chapter 2.0

Preparation Before Testing

8

2.1

Connecting the ESD Shoe Testing

8

2.2

Threshold Resistance Settings

9

2.3

Power Preparation

10

2.3.1

Installing and Replacing the Batteries

10

2.3.2

AC Adapter Connection

11

2.4

Turning Power On and Off

11

2.5

Wall Mounting

12

Chapter 3.0

Testing

12

3.1

ESD Shoe Testing

13

3.2

ESD Wrist Strap Testing

14

Chapter 4.0

External Output Function

14

4.1

Open Collector Output

14

4.2

RS-232C Communications

18

4.3

Card Read Technical Specifications

19

4.4

PC System Requirements

19

Chapter 5.0

Specification

20

5.1

Measurement Section

20

5.2

General Specifications

21

Chapter 6.0

Maintenance & Service

21

6.1

Battery Replacement Indicator

21

6.2

Error Messages

22

6.3

Before Returning the 3MShoes and Wrist Strap Tester 747 for Service

22

6.4

Cleaning

23

Chapter 7.0

Operational Verification Test of Shoes and Wrist Strap Tester 747

23

Regulatory Information

27

Warranty

29

1

Image 2
Contents 3M Shoes and Wrist Strap Tester Table of Contents Introduction InspectionExplanation of Safety Label Signal Words & Symbols Intended UsePage Overview Product OutlineLCD Indicators Side Panels Back SidePreparation Before Testing Connecting the ESD Shoe Testing PlateShoes Power Preparation Installing and Replacing the Batteries Power Saver Function Turning Power On and OffTurning Power Off AC Adapter ConnectionTesting Wall MountingALL setting is described in .1, Open Collector Output ESD Shoe Testing with the 3M Shoes and Wrist Strap TesterImportant Note Use single-conductor wrist straps only External Output Function Open Collector OutputInternal Circuit Test Result Output SettingsTest Result Output Terminal Shoe and Wrist Strap ALL Setting Open-Collector OutputSpecifications RS-232C CommunicationsPC System Requirements PC ConnectionCable Connections Measurement Section Measurement Resistance Range 0 to 200.0 MΩMaintenance & Service Battery Replacement IndicatorError Messages LCD can display the following error messagesOperational Verification Test CleaningTesting Considerations Test Set-Up Testing Wrist Strap RangesEquipment Required Wrist Test Table Testing Wrist Low Limit Refer to Wrist Test TableTesting Wrist High Limits Refer to Wrist Test Table Testing Shoe Ranges Testing Shoes Low Limits Refer to Shoes Test TableWeee Statement Regulatory InformationShoe Test Table CULus StatementFCC Electronic Solutions Division Static Control Products
Related manuals
Manual 40 pages 58.99 Kb