ProForm PFTL57908.0 manual Troubleshooting, Compatible with GFCI-equipped outlets

Page 22

TROUBLESHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please see the front cover of this manual. PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor

is plugged into a properly grounded outlet (see page 13). Use only a single-outlet surge suppres-

sor that meets all of the specifications described on page 13. IMPORTANT: The treadmill is not

compatible with GFCI-equipped outlets.

 

 

b. After the power cord has been plugged in, make sure that the key is inserted into the console.

c. Check the reset/off circuit breaker located on the

c

 

treadmill frame near the power cord. If the switch

 

protrudes as shown, the circuit breaker has

Tripped

Reset

tripped. To reset the circuit breaker, wait for five

minutes and then press the switch back in.

Position

Position

PROBLEM: The power turns off during use

 

 

SOLUTION: a. Check the reset/off circuit breaker (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b.Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c.Remove the key from the console. Reinsert the key into the console.

d.If the treadmill still will not run, please see the front cover of this manual.

PROBLEM: The console displays remain lit when you remove the key from the console

SOLUTION: a. The console features a display demo mode, designed to be used if the treadmill is displayed in a

store. If the displays remain lit when you remove the key, the demo mode is turned on. To turn off

the demo mode, hold down the Stop button for a few seconds. If the displays are still lit, see THE

INFORMATION MODE on page 20 to turn off the demo mode.

 

PROBLEM: The displays of the console do not function properly

 

 

SOLUTION: a. Remove the key from the console and UNPLUG

a

77

THE POWER CORD. With the help of a second

person, carefully tip the Uprights (77, 92) down.

 

 

There may be three #8 x 2" Screws (14) in the bot-

 

 

tom of the Belly Pan (73). If there are, remove

 

 

them. Note: A Phillips screwdriver with a shaft at

92

73

least 5 in. (13 cm) long is required. Then, raise the

Uprights.

 

14

 

 

 

 

14

22

Image 22
Contents Mon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MT QUESTIONS?Model No. PFTL57908.0 Serial No On the WEBTable of Contents Important Precautions Pulse sensor is not a medical devicePage Before YOU Begin Assembly Do not fully fold the Frame yet Make sure that the power cord is unpluggedTighten the Nut the Wheel must turn freely With a second Bolt Spacer 95, 3/8 x 4 Bolt 3/8 Star Washer Careful not to pinch the Wire HarnessTighten the Bolts yet Bolts yet Not Connected PROPERLY, the CON Sole MAY be Damaged When Screws before firmly tightening any of them Overtighten the Screws. Then, raiseRaise the Frame 48 to the position shown HOW to Plug in the Power Cord Operation and AdjustmentPRE-LUBRICATED Walking Belt Console Diagram Features of the ConsoleSelect the manual mode HOW to Turn on the PowerHOW to USE the Manual Mode Insert the key into the consoleMeasure your heart rate if desired. Before using Turn on the fan if desiredHOW to USE a Personal Trainer Quick ProgramHOW to Create Your OWN Quick Program Select a custom quick program Select a custom quick programs HOW to USE Your OWN Quick Program Follow your progress with the matrix and the displays Information Mode HOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USEProblem The power turns off during use TroubleshootingCompatible with GFCI-equipped outlets Problem The walking belt slows when walked on TopProblem Solution Workout Guidelines Exercise GuidelinesExercise Intensity Exercise FrequencyPart LIST-Model No. PFTL57908.0 Key No. Qty Description101 Red Wire, M/F 102 #8 x 1/2 Console Ground Screw Exploded Drawing A-Model No. PFTL57908.0 R0908A Exploded Drawing B-Model No. PFTL57908.0 R0908A Exploded Drawing C-Model No. PFTL57908.0 R0908A Exploded Drawing D-Model No. PFTL57908.0 R0908A Limited Warranty Ordering Replacement PartsIcon Health & Fitness, Inc., 1500 S W., Logan, UT