PROBLEM:

SOLUTION:

The walking belt is off-center or slips when walked on a. If the walking belt is off-center, first remove the

key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the hex key to turn the left idler roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walk- ing belt is centered.

b. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller bolts clock- wise, 1/4 of a turn. When the walking belt is cor- rectly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walk- ing belt centered. Then, plug in the power cord, in- sert the key, and carefully walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

24

Image 24
Contents QUESTIONS? Model No. PFTL57908.0 Serial NoMon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MT On the WEBTable of Contents Important Precautions Pulse sensor is not a medical devicePage Before YOU Begin Assembly Make sure that the power cord is unplugged Do not fully fold the Frame yetTighten the Nut the Wheel must turn freely Careful not to pinch the Wire Harness With a second Bolt Spacer 95, 3/8 x 4 Bolt 3/8 Star WasherTighten the Bolts yet Bolts yet Not Connected PROPERLY, the CON Sole MAY be Damaged When Screws before firmly tightening any of them Overtighten the Screws. Then, raiseRaise the Frame 48 to the position shown Operation and Adjustment HOW to Plug in the Power CordPRE-LUBRICATED Walking Belt Console Diagram Features of the ConsoleHOW to Turn on the Power HOW to USE the Manual ModeSelect the manual mode Insert the key into the consoleMeasure your heart rate if desired. Before using Turn on the fan if desiredHOW to USE a Personal Trainer Quick ProgramHOW to Create Your OWN Quick Program Select a custom quick programHOW to USE Your OWN Quick Program Select a custom quick programsFollow your progress with the matrix and the displays Information Mode HOW to Fold and Move the Treadmill HOW to Fold the Treadmill for Storage HOW to Move the Treadmill HOW to Lower the Treadmill for USETroubleshooting Problem The power turns off during useCompatible with GFCI-equipped outlets Problem The walking belt slows when walked on TopProblem Solution Exercise Guidelines Exercise IntensityWorkout Guidelines Exercise FrequencyPart LIST-Model No. PFTL57908.0 Key No. Qty Description101 Red Wire, M/F 102 #8 x 1/2 Console Ground Screw Exploded Drawing A-Model No. PFTL57908.0 R0908A Exploded Drawing B-Model No. PFTL57908.0 R0908A Exploded Drawing C-Model No. PFTL57908.0 R0908A Exploded Drawing D-Model No. PFTL57908.0 R0908A Ordering Replacement Parts Limited WarrantyIcon Health & Fitness, Inc., 1500 S W., Logan, UT