9. Sewing

9-3. Sewing with the folder in label attachment mode

¡Two types of label attachment mode can be used: when DIP switch D-2 is set to OFF, alternate label attachment is carried out, and when DIP switch D-2 is set to ON, continuous label attachment is carried out.

¡With alternate label attachment, the folder switches alternately between label attachment mode and automatic mode once for each sewing operation. During label attachment mode, the LABEL indicator e illuminates. If you would like to switch over the modes, press the LABEL button e.

¡With continuous label attachment, label attachment mode is active all the time. (The LABEL indicator e will re- main illuminated.)

r

e

u

 

 

 

t

q

 

 

y

o

i

@3

@4

1.Set the folder mode to label attachment mode.

NOTE:

Refer to page 18 for details on how to set the folder mode.

2.Press the STACKER button r so that the STACKER indicator is illuminated.

3.Place the workpiece t under the gauge assembly q. (*1)

4.Depress the foot switch @3. The vacuum system will start operating to hold the workpiece t in place.

5.Place the pocket material y on top of the gauge assembly q.

6.Depress the foot switch @3, and hold it in that condition. The intermediate work clamp u will be set down on top of the gauge assembly q and label setting will be possible.

Place the label i into the clamp o of the label attacher.

After setting the label i in place, release the foot switch @3. The clamp o of the label attacher will clamp the label i and then rotate to the folding position.

If you would like to reclamp the label i, depress the foot switch @3once more and keep it depressed. The label can then be reset.

7.Press the RESTART buttones @4simultaneously.

The pocket material y will be folded by the folder and the workpiece t and the pocket material y will then be moved to the machine head and sewing will start. (*2)

8.Once sewing is finished, the stacker will operate and the workpiece w will be stacked. The machine head and the work clamp will then return to the standby positions.

*If the LABEL indicator e is switched off, it means that automatic mode is active.

*1 If DIP switch D-1 has been set to ON, the gauge assembly q will retract. The gauge assembly q moves forward at the same time the vacuum system starts operating when the foot switch @3is depressed.

*2 If DIP switch A-1 has been set to ON, operation stops momentarily after folding has been completed so that the folding can be checked. When the RESTART buttones @4are pressed again simultaneously, operation continues as before.

27

BAS-761

Image 34
Contents BAS-761 Safety Instructions Environmental requirements Installation Cleaning Thread take-up cover Belt cover Guard bar Contents Names of Machine Components Names of Machine ComponentsSpecifications Installation Installation of the machine tableInstallation of the spool stand Removal of the fixing bolts from the machineConnection of the air hose Connection of the foot-switch connectorPositioning of the front supporter Installation positions for operation box and switch box Installation of the folding group assembly Before installationLubrication Upper threading Installing the needleCorrect operation X2.4 rotary hookRemoval of the bobbin Bobbin case threadingRemoval of the bobbin case X2.4 rotary hook X1.7 rotary hookBobbin thread winding Thread tension Thread take-up spring X2.4 rotary hook X1.7 rotary hookButton functions Operation box panel buttonesButton functions Sewing Speed button Thread Monitor button Thread Monitor indicatorTest button Test indicator Counter buttonEnter button Cancel buttonButton functions Bobbin Change button Arrow keys@0 Start button Switch box panel buttones@1 Reset button @2 Emergency Stop buttonFoot switch Restart buttonesSetting the sewing speed and the bar tacking speed Settings before sewingSetting the folder mode Settings before sewingTack Speed 3000 rpm Setting the lower thread counter Replacing the lower threadSetting the piece counter Setting the stacker roller feed amountSetting the date and time Change date DATE1998/10/1 Screen Change time TimePreparation for sewing Preparation for sewingRead sewing data Sewing with the folder in automatic mode SewingSewing with the folder in pattern matching mode Sewing with the folder in label attachment mode Sewing with the folder in step mode Test feeding To continue sewing Emergency stopTo stop the machine during sewing To interrupt sewing and return to the standby positionAdjustments Needle-bar height adjustmentPresser foot height adjustment Needle and rotary hook timingRemoval of the fixed knife Removal of the fixed knife and the movable knifeRemoval of the movable knife Stacker position adjustment Sewing clamp assembly number selection Sewing clamp assembly numberDIP switch positions Using the DIP switchesUsing the DIP switches Functions of operation panel DIP switchesUsing the DIP switches Table of error code Error code Contents Reset Emergency Stop button pressed 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone