Brother BAS-761 instruction manual Error code Contents Reset Emergency Stop button pressed

Page 46

12. Table of error code

Error code

Contents

Reset

 

 

 

E – 800

EMERGENCY STOP button pressed

Yes

 

 

 

E – 801

EMERGENCY STOP button pressed during sewing

Yes

 

 

 

E – 802

EMERGENCY STOP button pressed during programming

No

 

 

 

E – 803

EMERGENCY STOP button pressed during programming

Yes

 

 

 

E – 810

EMERGENCY STOP button is not connected

No

E – 820

No air, or air chuck is turned off

Yes

E – 821

No air, or air chuck is turned off

No

E – 830

X right overtravel switch activated

No

 

 

 

E – 840

X left overtravel switch activated

No

 

 

 

E – 850

Y up overtravel switch activated

No

 

 

 

E – 860

Y down overtravel switch activated

No

 

 

 

E – 870

X motor problem

No

E – 880

Y motor problem

No

E – 890

Machine head motor problem

No

E – 900

Outer work clamp cylinder malfunction or sensor malfunction

No

 

 

 

E – 901

Inner work clamp cylinder malfunction or sensor malfunction

No

 

 

 

E – 902

Gauge forward/back cylinder malfunction or sensor malfunction

No

 

 

 

E – 903

Base 10 cylinder malfunction or sensor malfunction

No

 

 

 

E – 910

X axis positioning error

No

 

 

 

E – 920

Y axis positioning error

No

 

 

 

E – 960

Clamp-in sensor malfunction

No

E – 970

Clamp malfunction

No

*If the primary-side voltage is lower than the rated level at low temperatures, the error message “E-890” may appear at the sewing start. If this happens, set DIP switch A-7 to ON.

39

BAS-761

Image 46
Contents BAS-761 Safety Instructions Environmental requirements Installation Cleaning Thread take-up cover Belt cover Guard bar Contents Names of Machine Components Names of Machine ComponentsSpecifications Installation Installation of the machine tableInstallation of the spool stand Removal of the fixing bolts from the machineConnection of the air hose Connection of the foot-switch connectorPositioning of the front supporter Installation positions for operation box and switch box Installation of the folding group assembly Before installationLubrication Upper threading Installing the needleCorrect operation X2.4 rotary hookRemoval of the bobbin Bobbin case threadingRemoval of the bobbin case X2.4 rotary hook X1.7 rotary hookBobbin thread winding Thread tension Thread take-up spring X2.4 rotary hook X1.7 rotary hookButton functions Operation box panel buttonesButton functions Sewing Speed button Thread Monitor button Thread Monitor indicatorTest button Test indicator Counter buttonEnter button Cancel buttonButton functions Bobbin Change button Arrow keys@0 Start button Switch box panel buttones@1 Reset button @2 Emergency Stop buttonFoot switch Restart buttonesSetting the sewing speed and the bar tacking speed Settings before sewingSetting the folder mode Settings before sewingTack Speed 3000 rpm Setting the lower thread counter Replacing the lower threadSetting the piece counter Setting the stacker roller feed amountSetting the date and time Change date DATE1998/10/1 Screen Change time TimePreparation for sewing Preparation for sewingRead sewing data Sewing with the folder in automatic mode SewingSewing with the folder in pattern matching mode Sewing with the folder in label attachment mode Sewing with the folder in step mode Test feeding To continue sewing Emergency stopTo stop the machine during sewing To interrupt sewing and return to the standby positionAdjustments Needle-bar height adjustmentPresser foot height adjustment Needle and rotary hook timingRemoval of the fixed knife Removal of the fixed knife and the movable knifeRemoval of the movable knife Stacker position adjustment Sewing clamp assembly number selection Sewing clamp assembly numberDIP switch positions Using the DIP switchesUsing the DIP switches Functions of operation panel DIP switchesUsing the DIP switches Table of error code Error code Contents Reset Emergency Stop button pressed 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone