John Lewis JLTDC12 instruction manual Adjusting the level of conductivity

Page 23

2.Press simultaneously the Intensive and Anti-creasebuttons and hold down for approx. 5 seconds.

Adjusting the level of conductivity

Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to geographical locations thus varying its conductivity values.

Relevant variations of the conductivity of the water compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of the cycle. Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity values of the water.

In order to establish the conductivity of the water in your area please contact your water board.

1.Turn the programme selector to any programme.

2.Press simultaneously the Anti-creaseand Start/Pause buttons and hold down for approx. 5 seconds.

3.Press the Start/Pause button until you set desired level:

low conductivity <300 µS/cm

medium conductivity

300-600 µS/cm

high conductivity >600 µS/cm

4.To memorize setting press simultaneously the Anti-creaseand Start/Pause buttons or turn knob to Off position

23

Image 23
Contents Condenser dryer with heat pump General safety Important safety informationCause an explosion. Only tumble dry items washed with water InstallationUse Spin the laundry well before drying Child safetyEnvironmental tips Environmental informationPage Contents Machine settings Description of the appliance Time button Display Dry time Programme selector and Off switchControl panel Before first useProgrammes Programme chartPreparing laundry Sorting and preparing laundrySorting laundry Selecting the programme Switching machine onDaily use Door opening and laundry loadingAnti-crease AlarmBe removed at any time during the anti- crease phase IntensiveSetting child lock Delay startDrying cycle complete / removing laundry Starting the programmeChanging programme Open door Maintenance and cleaningCleaning fluff filter Locks into the interlock Filter into the brackets on the loadingDoor until they snap into place Re-insert fine filterEmptying the water reservoir Cleaning the door sealWater reservoir has a volume of approx litres Cleaning heat exchanger filters When doing this, please use rubber gloves Cleaning the drumWhat to do if Clean operating screen and housingReplacing the drum light Machine settingsAlarm permanent on/off Press the Start/Pause button until you set desired level Adjusting the level of conductivityConsumption values Technical specificationsAppliance positioning InstallationTransporting the appliance Electrical connection Removing transport safety packagingGreen & Yellow Brown Blue Cord Clamp Green and Yellow Earth Blue Neutral Brown LiveMod Repairs after sales serviceDoor reversal Spare parts Page Page 136912010-00-052010