Kenmore 796.8172 manual Using the Duct Length Chart below

Page 14

INSTALLATION INSTRUCTIONS

VENTING THE DRYER

IMPORTANT! CHECK YOUR EXHAUST SYSTEM FOR PROBLEMS

The most common cause of dryer problems is poor exhaust venting. Before installing your new dryer, check the items listed below to make sure you get the best possible performance. This can save you time and money by reducing cycle times and increasing energy efficiency.

DIRTY OR DAMAGED EXHAUST DUCTS. Lint builds up in exhaust ducts over time. This decreases the airflow and makes the dryer work harder. Visually inspect your ducts from both ends and have them cleaned if they have not been cleaned recently.

WRONG VENT MATERIAL. Check your vent to make sure it is rigid or semi-rigid metal ducting. If your venting is plastic or flexible foil, have it replaced before using the dryer.

RESTRICTED OR DAMAGED VENT HOOD. Check your vent hood outside. It must be clean and free of lint buildup. Check the damper and make sure it opens fully and easily.

EXCESSIVELY LONG VENT. Measure the length of your exhaust system and count the elbows. Use the chart below to see if your duct is too long. If it is too long, have the duct routed to another location that is within the venting guidelines.

DO NOT USE PLASTIC OR FOIL VENTING. The transition duct from your dryer to the wall must be rigid or semi-rigid metal ducting. If your old transition duct is plastic or foil, REPLACE IT with semi-rigid metal ducting.

Using the DUCT LENGTH CHART (below)

1Find your vent hood type in the chart below.

2Select the row that matches the number of elbows in your dryer duct run.

3Look to the right of the elbow number for the maximum duct length for your installation. Longer duct length will result in reduced drying performance, longer dry times and increased energy consumption. Extremely long ducts can even shorten the life of the dryer.

DO NOT exceed the maximum length for the vent hood type and number of elbows used.

 

 

Vent Hood Type

Number of 90°

Maximum length of 4" (10.2 cm )

 

 

Elbows

diameter rigid metal duct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended

0

65 feet (19.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

55 feet (16.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

47 feet (13.7 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

36 feet ( 11.0 m )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"

 

 

4"

 

 

 

 

 

 

 

 

4

28 feet (8.5 m)

(10.2 cm )

 

 

 

 

(10.2 cm )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only for Short-Run Installations

0

55 feet (16.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

47 feet (13.7 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

41 feet (12.5 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

30 feet (9.1 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(6.35 cm )

4

22 feet (6.7 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. Using more than four 90° elbows is not recommended.

14

Image 14
Contents Steam Dryer HOW to USE Features and BenefitsInstallation Instructions Troubleshooting GuideRead ALL Instructions Before USE Basic Safety Precautions Safety Instructions for Installation WeatherSafety Instructions for Steam Functions KEY Parts and Components Location Requirements KEY Dimensions and SpecificationsAdditional instructions for closet installations Choose the Proper LocationInstallation with Optional Pedestal Base or Stacking KIT Optional AccessoriesElectrical Requirements for GAS Models only Connecting GAS DryersGAS Requirements GAS Models ONlY Gas shutoff valve must be installed within 6 ft Connecting the Gas SupplyHigh-Altitude Installations Stainless Steel FlexibleElectrical Requirements Connecting Electric Dryers Electrical Requirements for Electric Models OnlyFour-Wire Power Cord Connecting Electric DryersConnecting Electric Dryers Three-Wire Power CordUsing the Duct Length Chart below Venting the Dryer Routing and Connecting DuctworkConnecting the Dryer Vent Correct VentingReversing the Door Swing Wear gloves during installationLeveling the Dryer Hole capChecking Venting Final Installation CheckTesting Dryer Heating DamagedControl Panel Features Operating the Dryer Certified by NSF Cycle GuideAuto DRY Timed DRY = default setting= available option Group Similar Items Sorting LoadsFabric Care Labels Loading the DryerTime and Status Display DRY Level Cycle Modifier ButtonsTemp Control Timed DRYTo recall a MY Cycle Cycle Options and Special FeaturesTo save a MY Cycle Or articlesUsing the Static Shield option Steam FeaturesUsing the Steam Refresh cycle Using the Easy Iron optionDrawer Filling the Steam FeederTap water Pull out the drawerCleaning the Interior Regular CleaningCleaning the Exterior Cleaning Around and Under the DryerMaintaining the Exhaust System Check Vent IndicatorMaintaining the Exhaust System Check Vent OperationUsing the Kenmore Connect System Kenmore Connect SystemBefore Calling for Service Problem Possible Cause SolutionsClothes are wrinkled Before Calling for Service Problem Possible Cause SolutionsClothes take too long to dry Clothes are shrinkingTE1 or tE2 Lint on clothes Kenmore Elite Limited Warranty Disclaimer of implied warranties limitation of remediesPage Instrucciones DE USO Funciones Y VentajasInstrucciones Para LA Instalación Acuerdos maestros de protecciónLEA Todas LAS Instrucciones Antes DE Utilizar Este Producto Producto Lea todas las instrucciones antes de utilizar la secadoraNo toquetee los controles Inadecuada delInstrucciones DE Seguridad Para LA Instalación Coloque la secadora a una altura mínima de 46 cmInstrucciones DE Seguridad Para LAS Funciones CON Vapor Piezas Y Componentes Clave Escoja EL Lugar Adecuado Dimensiones Y Especificaciones ClaveRequisitos DE Ubicación Espacios DE InstalaciónAccesorios Opcionales Explosión, incendio o, incluso, muerte Requisitos Eléctricos Sólo Para Modelos DE GASIncendio o, incluso, muerte Si únicamente se dispone de una toma de corriente deInstalaciones en altitudes elevadas Conexión DE LAS Secadoras DE GAS continuaciónConexión al suministro de gas Requisitos Eléctricos Conexión DE LAS Secadoras Eléctricas Requisitos eléctricos sólo para modelos eléctricosConexión DE LAS Secadoras Eléctricas continuación Green WireDelWineutroe Power Cord Ground Wire Conexión DE LAS Secadoras EléctricasVentilación DE LA Secadora Uso del Cuadro DE Longitudes DEL Conducto a continuaciónMida la longitud del conducto. no sobrepase la longitud Colocación y conexión de los conductosConexión del conducto de ventilación de la secadora Orificio Nivelación DE LA SecadoraInversión DE LA Puerta Verifique que la puerta funcione correctamente yComprobación de la ventilación Comprobación Final DE LA InstalaciónPrueba de calentamiento de la secadora Funciones DEL Panel DE Control Funcionamiento DE LA Secadora Guía DE Ciclos Secado Manual = opción disponibleAgrupación de prendas similares Clasificación DE CargasEtiquetas de cuidado de las prendas Carga DE LA SecadoraIndicador DEL Filtro DE Pelusas Pantalla DE Tiempo Y EstadoPantalla DE Tiempo Indicadores DE Estado DEL CicloAviso Sonoro Control DE TemperaturaNivel DE Secado Instalación Y USO DE LA Rejilla DE Secado Opciones DE Ciclos Y Funciones EspecialesUso de la opción Secado Húmedo Para guardar un ciclo personalizadoUso de la opción Protección Antiestática Funciones DE VaporUso del Ciclo Refrescado CON Vapor Uso de la opción Planchado FácilAlimentadorSteam chorroON LY Fededervapor Solo Llenado del Alimentador de vaporCajón Hale la gaveta Levante el alimentador de vapor Limpieza del interior Limpieza RegularLimpieza del exterior Limpieza alrededor de la secadora y debajo de ellaIndicador Check Vent Mantenimiento DEL Sistema DE VentilaciónMantenimiento del sistema de ventilación Funcionamiento de Check VentUso del sistema Kenmore Connect NotaProblema Causa posible Soluciones Antes DE Solicitar Asistencia TécnicaLa carga no se ha agrupado correctamente Sucios o son demasiado largosObstruidos, atascados ni dañados Resultados del sensor, ya que se secan antesAntes DE Solicitar Asistencia Técnica continuación Garantía limitada de Kenmore Elite Nota Nota Nota LE-FOYERMC Sears Parts & Repair Service CenterSU-HOGAR MY-HOME1-800-469-4663