American Dryer Corp MLG-130DR (HSI) SPECIFICATIONS/COMPONENT Identification, Specifications

Page 10

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

130 lbs.

 

60 kg

 

 

 

 

 

TUMBLER (BASKET) DIAMETER

44-1/2”

 

113 cm

TUMBLER (BASKET) DEPTH

42-1/2”

 

107.9 cm

TUMBLER (BASKET) MOTOR

3/4 HP

 

.560 kw

BLOWER MOTOR

3 HP

 

2.238 kw

DOOR OPENING (DIAMETER)

31-3/8”

 

79.7 cm

TUMBLER (BASKET) VOLUME

38.2 cu. ft.

 

1.08 cu.m.

DRYERS PER 20’/40’ CONTAINER

 

3/7

 

 

 

 

 

DRYERS PER 45’/48’ TRUCK

 

9/9

 

 

 

 

 

 

VOLTAGE AVAILABLE

208-460v

3, 4w 50/60Hz

 

 

 

 

 

 

HEAT INPUT

300,000 btu/hr

 

75,600 kcal/hr

Gas

APPROX. WEIGHT (UNCRATED)

1,500 lbs.

 

680.4 kg

APPROX. WEIGHT (CRATED)

1,725 lbs.

 

782.5 kg

 

AIRFLOW

1,750 cfm

 

49.6 cmm

 

INLET PIPE SIZE

1”

 

2.54 cm

 

 

 

 

 

Shaded areas are stated in metric equivalents

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

6

Image 10
Contents MLG-130DR HSI Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Front View Illus. NoDryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Rear of Dryer refer to the illustration onPage Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Be Reduced Anywhere Down Stream of the Dryer Page Multiple Dryer Common Venting Page Electrical Information Electrical RequirementsElectrical Service Specifications MLG-130DR GasElectrical Connections GAS Information Technical Data Gas Specifications Gas Connections Inlet connection ---------- 1-inch N.P.TType of Gas Liquid Propane L.P. GasPage Preparation for OPERATION/START-UP Preoperational TestsGas Operating Instructions Basket CoatingShut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationReturning Warranty Parts Page Routine Maintenance CleaningAdjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Start the drying cycle Manual Reset HI-LIMIT Instructions For Phase 6 ModelsADC113130 1- 03/28/00-25