IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid detergent works well).

WARNING: NEVER TEST FOR LEAKS WITHA FLAME!!!

ALL components/materials must conform to National Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.

It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of ALL the appliance BTU’s being supplied.

IMPORTANT: The dryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).

26

Image 30
Contents MLG-130DR HSI Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Front View Illus. NoDryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Rear of Dryer refer to the illustration onPage Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Be Reduced Anywhere Down Stream of the Dryer Page Multiple Dryer Common Venting Page Electrical Information Electrical RequirementsElectrical Service Specifications MLG-130DR GasElectrical Connections GAS Information Technical Data Gas Specifications Gas Connections Inlet connection ---------- 1-inch N.P.TType of Gas Liquid Propane L.P. GasPage Preparation for OPERATION/START-UP Preoperational TestsGas Operating Instructions Basket CoatingShut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsReturning Warranty Parts Page Routine Maintenance CleaningAdjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Start the drying cycle Manual Reset HI-LIMIT Instructions For Phase 6 ModelsADC113130 1- 03/28/00-25