American Dryer Corp MLG-130DR (HSI) Manual Reset HI-LIMIT Instructions, For Phase 6 Models

Page 44

SECTION IX

BURNER and LINT (TUMBLER) CHAMBER

MANUAL RESET HI-LIMIT INSTRUCTIONS

(FOR PHASE 6 MODELS)

This dryer was manufactured with a manual reset burner hi-limit (gas models only) and tumbler/lint chamber hi-limit thermostat which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 6 computer will display an error code with an audio indication. If the tumbler/lint chamber hi-limit thermostat is open, the display will read “dRUM SAFETY FAIL.” If the burner hi-limit thermostat is open, the display will read “bURNER SAFETY FAIL.”

If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable error code described above along with an audio indication. If the drum temperature is above 100º F (38º C), the dryer will continue to run with no heat for three (3) minutes or until the drum temperature has flattened below 100º F (38º C). The clear/stop button on the Phase 6 keyboard (touchpad) must be pressed to clear the error condition. The open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner operation.

The location of the burner hi-limit is on the right side of the burner box and the tumbler hi-limit is located in the lint chamber area.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.

IMPORTANT

This dryer is equipped with a burner hi- limit and tumbler/lint chamber hi-limit ther- mostat which must be reset manually.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.

ADC P/N: 114093

40

Image 44
Contents MLG-130DR HSI Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Front View Illus. NoDryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Rear of Dryer refer to the illustration onPage Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Be Reduced Anywhere Down Stream of the Dryer Page Multiple Dryer Common Venting Page Electrical Information Electrical RequirementsElectrical Service Specifications MLG-130DR GasElectrical Connections GAS Information Technical Data Gas Specifications Gas Connections Inlet connection ---------- 1-inch N.P.TType of Gas Liquid Propane L.P. GasPage Preparation for OPERATION/START-UP Preoperational TestsGas Operating Instructions Basket CoatingShut Down Instructions Parts SERVICE/PARTS InformationService Returning Warranty Parts Warranty InformationReturning Warranty Cards Page Routine Maintenance CleaningAdjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Start the drying cycle Manual Reset HI-LIMIT Instructions For Phase 6 ModelsADC113130 1- 03/28/00-25