American Dryer Corp MLG-130DR (HSI) Preparation for OPERATION/START-UP, Preoperational Tests

Page 31

H. PREPARATION FOR OPERATION/START-UP

The following items should be checked before attempting to operate the dryer:

1.Read ALLCAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.

2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label located in the front top console area as shown in the illustration on page 9. In the case of 208 VAC or 230 VAC THE SUPPLY VOLTAGE MUST MATCH THE ELECTRIC SERVICE EXACTLY.

3.Check to assure that the dryer is connected to the type of heat/gas indicated on the dryer data label.

4.The sail switch damper assembly was installed and pre-adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to assure that this important safety control is functioning.

5.Be sure that ALL gas shut-off valves are in the open position.

6.Be sure ALL back panels (guards) and electric box covers have been replaced.

7.Check ALL service doors to assure that they are closed and secured in place.

8.Be sure the lint drawer is securely in place.

NOTE: LINT DRAWER MUST BE ALLTHE WAY IN PLACE TO ACTIVATE THE SAFETY SWITCH OTHERWISE THE DRYER WILL NOT START.

9.Rotate the tumbler (basket/drum) by hand to be sure it moves freely.

10.Check bolts, nuts, screws, terminals, and fittings for security.

11.Check tumbler bearing set screws to insure they are ALL tight.

I. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer.

2.Make sure the main door is closed and the lint drawer is securely in place.

3.Refer to the Operating Instructions for starting your particular model dryer.

4.Check to insure that the tumbler (basket) starts in the clockwise (CW) direction. Additionally, check the direction of the blower motor impellor (fan) to insure that the impellor (fan) rotates in the clockwise (CW) direction as viewed from the front. If it is, the phasing is correct. If the phasing is incorrect, reverse two (2) of the leads at L1, L2, or L3 of the power supply connections made to the dryer.

27

Image 31
Contents MLG-130DR HSI Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Dryer Front View Illus. No Component IdentificationDryer Rear View Illus. No Location Requirements Installation ProceduresRear of Dryer refer to the illustration on UNPACKING/SETTING UPPage Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Be Reduced Anywhere Down Stream of the Dryer Page Multiple Dryer Common Venting Page Electrical Requirements Electrical InformationMLG-130DR Gas Electrical Service SpecificationsElectrical Connections GAS Information Gas Connections Inlet connection ---------- 1-inch N.P.T Technical Data Gas SpecificationsLiquid Propane L.P. Gas Type of GasPage Preoperational Tests Preparation for OPERATION/START-UPGas Basket Coating Operating InstructionsShut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationReturning Warranty Parts Page Cleaning Routine MaintenanceLubrication AdjustmentsTiming Legend Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Start the drying cycle For Phase 6 Models Manual Reset HI-LIMIT InstructionsADC113130 1- 03/28/00-25