American Dryer Corp MLG-130DR (HSI) Electrical Information, Electrical Requirements

Page 24

F.ELECTRICAL INFORMATION

1.Electrical Requirements

It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual can result in personal injury or component failure.

NOTE: Component failure due to improper installation will VOID THE WARRANTY.

Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. DO NOT use aluminum wire which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making ALL service connections.

NOTE: The use of aluminum wire will VOID THE WARRANTY.

NOTE: Wiring diagrams are affixed to the inside at the top front control door and the rear upper back guard/panel.

20

Image 24
Contents MLG-130DR HSI Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Front View Illus. NoDryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Rear of Dryer refer to the illustration onPage Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Be Reduced Anywhere Down Stream of the Dryer Page Multiple Dryer Common Venting Page Electrical Information Electrical RequirementsElectrical Service Specifications MLG-130DR GasElectrical Connections GAS Information Technical Data Gas Specifications Gas Connections Inlet connection ---------- 1-inch N.P.TType of Gas Liquid Propane L.P. GasPage Preparation for OPERATION/START-UP Preoperational TestsGas Operating Instructions Basket CoatingShut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsReturning Warranty Parts Page Routine Maintenance CleaningAdjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Start the drying cycle Manual Reset HI-LIMIT Instructions For Phase 6 ModelsADC113130 1- 03/28/00-25