Maytag W10057351A Install Vent System, Install Leveling Legs, Connect Vent, Connect Inlet Hose

Page 18

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number of 90º

Type of vent

Box or louvered

Angled hoods

turns or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

Install Vent System

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

3.Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1.To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.

2.Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.

3.Examine the leveling legs. Find the diamond marking.

4.Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.

5.Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

Connect Vent

1.Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.

2.Move dryer into its final location. Do not crush or kink vent.

3.Once the exhaust vent connection is made, remove the corner posts and cardboard.

Connect Inlet Hose

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

1.Turn cold water faucet off and remove washer inlet hose.

2.Remove old rubber washer from inlet hose and replace with new rubber washer provided. If space permits, attach the brass female end of the “Y” connector to the cold water faucet.

NOTE: If “Y” connector can be attached directly to cold water faucet, go to Step 6. If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. Continue with Step 3.

3.Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet.

18

Image 18
Contents Sécheuse Électrique W10057351ATable of Contents Dryer Safety Your safety and the safety of others are very importantInstallation Instructions Optional PedestalCustom undercounter installation Dryer only Installation clearancesDryer Dimensions Location RequirementsCloset installation Dryer only Recessed or closet installation Dryer on pedestalElectrical Requirements U.S.A. Only Mobile home Additional installation requirementsMobile home installations require It is your responsibilityIf connecting by direct wire Grounding InstructionsPower Supply Cord Direct Wire Style 1 Power supply cord strain reliefElectrical Connection U.S.A. Only Style 2 Direct wire strain relief Wire connection Power supply cord Wire connection Direct wire5cm BDE CG F Page If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Optional exhaust installations ExhaustAlternate installations for close clearances Special provisions for mobile home installationsDetermine vent path Vent system chart Install Vent SystemInstall Leveling Legs Connect VentLevel Dryer Canada Complete InstallationU.S.A If the dryer will not start, check the followingDryer USE Starting Your DryerTo use a Sensor Cycle How Sensor Cycles Work To use a Timed CycleControl Lock Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Indicator CyclesSteam Preset Cycle Settings Sensor Cycle SettingsManual Preset Cycle Settings Timed CyclesOptional Features Changing Cycles, Options and ModifiersDrying Rack Option Cleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareWater Inlet Hoses Vacation, Storage and Moving CareChanging the Drum Light Troubleshooting Dryer Operation„ Are fabric softener sheets blocking the grille? „ Was the Air Dry temperature setting selected?Dryer Results „ Is the exhaust vent the correct length?Stains on load or drum Cycle time too shortLint on load Loads are wrinkledU.S.A Assistance or ServiceIf you need replacement parts CanadaMaytag Major Appliance Warranty This limited warranty does not coverSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteConservez CES Instructions Pièces fournies Instructions DinstallationPiédestal facultatif Pièces nécessairesExigences demplacement Espacement recommandé pour linstallation dans un placard Installation dans un placard Sécheuse seulementLinstallation dans une maison mobile exige Spécifications électriques’est à l’utilisateur qu’incombe la responsabilité de Exigences concernant lévacuation En cas dutilisation du système dévacuation existantCoudes Conduit métallique rigideConduit métallique flexible Brides de serrageInstallations d’évacuation facultatives Autres installations où le dégagement est réduitPlanification du système d’évacuation Déterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationInstallation des pieds de nivellement Mise à niveau de la sécheuseRaccordement du tuyau dalimentation Achever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse Utilisation dun programme de détectionUtilisation dun programme minuté Comment fonctionnent les programmes de détectionVerrouillage des commandes Arrêt de la sécheusePause ou remise en marche Conseils pour les programmes Témoins lumineuxProgrammes Caractéristiques supplémentaires Changement des programmes, options et Modificateurs Damp Dry Signal signal de séchage humideCycle signal signal de programme Grille de séchageSéchage sur grille Réglage Temp Durée Chandails en laine Nettoyage de lemplacement de La sécheuseEntretien DE LA Sécheuse Jouets rembourrés ou oreillersRetrait de la charpie accumulée Nettoyage du filtre à charpieNettoyage de l’intérieur de la sécheuse Tuyaux darrivée deauRéutilisation de la sécheuse Changement de l’ampoule d’éclairage Du tambourHiverisation de la sécheuse Changement de l’ampoule du tambourLa sécheuse ne fonctionne pas DépannageFonctionnement de la sécheuse Absence de chaleur La sécheuse affiche un message codé„ Le conduit dévacuation a-t-il la longueur appropriée? „ La sécheuse est-elle installée dans un placard?Résultats de la sécheuse „ Le programme automatique se termine-t-il trop tôt?Assistance OU Service Garantie DES Gros Appareils Ménagers Maytag La présente garantie limitée ne couvre pasW10057351A