Recommended installation spacing for cabinet installation

 

 

 

 

3"*

„ For cabinet installation, with a door, minimum ventilation openings in the top of the

 

14" max.*

 

(7.6 cm)

 

48 in.2*

 

cabinet are required.

 

 

(35.6 cm)

 

 

 

 

 

(310 cm 2)

 

 

 

 

18" min.*

 

 

7"* (17.8 cm)

7"* (17.8 cm)

 

 

 

 

 

 

(45.72 cm)

 

 

 

 

 

 

 

24 in.2*

 

 

 

 

 

 

(155 cm 2)

3"*

 

 

 

 

 

 

 

9"*

 

 

 

 

(7.6 cm)

 

1"*

 

5"**

 

 

 

(22.9 cm)

31½"

 

 

 

 

(2.5 cm)

(80 cm) (12.7 cm)

 

 

 

 

 

A

 

 

B

 

 

A. Side view - closet or confined area

B. Closet door with vents

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

5"**

31¹ "

1"*

1"

27"

1"

(12.7 cm)

(80.0 cm) (2.5 cm) (2.5 cm)(68.6 cm) (2.5 cm)

 

 

 

 

 

14" max.*

 

 

 

 

 

 

(35.6 cm)

*Required spacing

 

 

 

 

18" min.*

 

 

 

 

**For side or bottom venting, 0" (0 cm) spacing is allowed.

 

 

 

 

(45.72 cm)

 

 

 

 

 

 

Recommended installation spacing for recessed or closet installation, with

 

 

 

 

 

 

stacked washer and dryer

 

 

 

 

 

 

The dimensions shown are for the recommended spacing.

 

 

 

 

 

 

48 in.2 *

1"

27"

1"

1"*

31½"

5"**

(310 cm2)

(2.5 cm)

(68.6 cm)

(2.5 cm)

(2.5 cm)

(80 cm)

(12.7 cm)

 

 

A

 

 

B

 

3"* (7.6 cm)

 

 

 

 

 

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

 

3"* (7.6 cm)

24 in.2 *

1"* (2.5 cm)

(155 cm2)

 

*Required spacing

6

Image 6
Contents Sécheuse Électrique W10057351ATable of Contents Dryer Safety Your safety and the safety of others are very importantInstallation Instructions Optional PedestalCustom undercounter installation Dryer only Installation clearancesDryer Dimensions Location RequirementsCloset installation Dryer only Recessed or closet installation Dryer on pedestalElectrical Requirements U.S.A. Only Mobile home Additional installation requirementsMobile home installations require It is your responsibilityIf connecting by direct wire Grounding InstructionsPower Supply Cord Direct Wire Style 1 Power supply cord strain reliefElectrical Connection U.S.A. Only Style 2 Direct wire strain relief Wire connection Power supply cord Wire connection Direct wire5cm BDE CG F Page If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Optional exhaust installations ExhaustAlternate installations for close clearances Special provisions for mobile home installationsDetermine vent path Vent system chart Install Vent SystemInstall Leveling Legs Connect VentLevel Dryer Canada Complete InstallationU.S.A If the dryer will not start, check the followingDryer USE Starting Your DryerTo use a Sensor Cycle How Sensor Cycles Work To use a Timed CycleControl Lock Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Indicator CyclesSteam Preset Cycle Settings Sensor Cycle SettingsManual Preset Cycle Settings Timed CyclesOptional Features Changing Cycles, Options and ModifiersDrying Rack Option Cleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareWater Inlet Hoses Vacation, Storage and Moving CareChanging the Drum Light Troubleshooting Dryer Operation„ Are fabric softener sheets blocking the grille? „ Was the Air Dry temperature setting selected?Dryer Results „ Is the exhaust vent the correct length?Stains on load or drum Cycle time too shortLint on load Loads are wrinkledU.S.A Assistance or ServiceIf you need replacement parts CanadaMaytag Major Appliance Warranty This limited warranty does not coverSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteConservez CES Instructions Pièces fournies Instructions DinstallationPiédestal facultatif Pièces nécessairesExigences demplacement Espacement recommandé pour linstallation dans un placard Installation dans un placard Sécheuse seulementLinstallation dans une maison mobile exige Spécifications électriques’est à l’utilisateur qu’incombe la responsabilité de Exigences concernant lévacuation En cas dutilisation du système dévacuation existantCoudes Conduit métallique rigideConduit métallique flexible Brides de serrageInstallations d’évacuation facultatives Autres installations où le dégagement est réduitPlanification du système d’évacuation Déterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationInstallation des pieds de nivellement Mise à niveau de la sécheuseRaccordement du tuyau dalimentation Achever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse Utilisation dun programme de détectionUtilisation dun programme minuté Comment fonctionnent les programmes de détectionVerrouillage des commandes Arrêt de la sécheusePause ou remise en marche Conseils pour les programmes Témoins lumineuxProgrammes Caractéristiques supplémentaires Changement des programmes, options et Modificateurs Damp Dry Signal signal de séchage humideCycle signal signal de programme Grille de séchageSéchage sur grille Réglage Temp Durée Chandails en laine Nettoyage de lemplacement de La sécheuseEntretien DE LA Sécheuse Jouets rembourrés ou oreillersRetrait de la charpie accumulée Nettoyage du filtre à charpieNettoyage de l’intérieur de la sécheuse Tuyaux darrivée deauRéutilisation de la sécheuse Changement de l’ampoule d’éclairage Du tambourHiverisation de la sécheuse Changement de l’ampoule du tambourLa sécheuse ne fonctionne pas DépannageFonctionnement de la sécheuse Absence de chaleur La sécheuse affiche un message codé„ Le conduit dévacuation a-t-il la longueur appropriée? „ La sécheuse est-elle installée dans un placard?Résultats de la sécheuse „ Le programme automatique se termine-t-il trop tôt?Assistance OU Service Garantie DES Gros Appareils Ménagers Maytag La présente garantie limitée ne couvre pasW10057351A