Sterling 882.00268.00 specifications Machine-Mount Installation

Page 16

Machine-Mount Installation

In this installation, the RPV is mounted directly to the material inlet of the hopper loader or vacuum hopper it will serve. The hopper loader or vacuum hopper inlet tube provides the support for the RPV.

WARNING! Make sure that the hopper loader or vacuum hopper inlet can support the weight of the RPV (approximately 10 lbs.) and any unsupported material supply hose. A properly-installed hopper loader or vacuum hopper can support 250 lbs. of downward force. If you are installing your RPV on equipment from another manufacturer, consult them for advice on support capabilities.

1.Check the RPV single outlet tube diameter and the hopper loader inlet size to be sure you have the necessary coupler and transition tube (if needed) to connect the RPV to the hopper inlet.

2.Chamfer and smooth the hopper loader or vacuum hopper inlet tube to prevent damage to the O-rings inside the tube coupler.

3.Apply silicone lubricant or equivalent to the inside of the tube coupler to ease insertion.

4.Insert the single material outlet tube into the tube coupler past the O-ring. Be careful to avoid damaging the O-ring.

5.Slide the RPV onto the hopper loader or vacuum hopper with a side-to-side motion. Be sure the tube passes the O-ring for an air-tight seal. Avoid damaging the O-ring.

6.Tighten the set screws in the tube coupler to lock the RPV in place.

7.Attach the material pick-up wands to the RPV inlet tubes using flex hose and hose clamps. Route the material conveying hoses so they don't interfere with workspace or create a tripping hazard.

Remote Proportioning Valve

Chapter 4: Installation

15 of 30

Image 16
Contents SPV Remote Proportioning Valve Parts and Service Department Shipping Info Table of Contents Troubleshooting How to Use This Manual SafetySafety Symbols Used in this Manual Remote Proportioning Valve Safety Safety General Safety Information Wear Safety Glasses and Work GlovesPage Functional Description Models Covered in This ManualGeneral Description How it WorksTypical Features and Components RPV- B and DWall Mount Installation InstallationMounting the RPV Wall-Mount Configuration Floor-Mount Installation Floor-Mount ConfigurationMachine-Mount Installation Installing the RPV Controls Installing the RPV-A Autoload Knob Box ControlKnob Box Assembly RPV-B or RPV-D Standalone Connection Diagram Standalone Junction Box Assembly Installing the RPV-C 9953 and 9963 Hopper Loader Control RPV-C to 9953 or 9963 Connection DiagramPower Switch and Indicator OperationKnob Box Operation Ratio KnobStandalone Control Operation Hopper Loader Conversion Operation ExampleWeight Test for Accurate Proportioning Troubleshooting IntroductionProblem Possible cause Solution Customer Satisfaction Warranty Program Technical SpecificationsAppendix Electrical RequirementsDrawings and Diagrams RPV DimensionsRPV Assembly Drawing and Parts Breakdown Service Department Technical AssistanceParts Department Sales Department