FREQENTLY ASKED QUESTIONS
What is the reason for modules to switch on/off spontaneously?
It is possible that a Marmitek
My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or Marmitek
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to be disturbed when more than one TM13 is transmitting. TM13’s will wait for a quite power line before transmitting their data. To prevent your Marmitek
What is the maximum load on connections on the UM7206 module?
•Without additional protective housing: maximum 24 VDC/5A.
•With a protective housing which removes all risks of electric shocks: maximum load 230 VAC/500mA.
Do you still have questions? Please check out www.marmitek.com for more information.
TECHNICAL SPECIFICATIONS
Power supply: | 230VAC 50 Hz |
Power consumption: | < 20 mA capacitive |
Switching power: | 5A at 24 VDC |
Signal sensitivity: | 15 mVpp min., 50mVpp max. at 120 kHz |
Input impedance: | > 55 Ohm |
Responds to | |
Connectors: | 2 x screw connector |
Ambient temperature: | |
| |
Dimensions: | 55x90x38mm |
6 | © MARMITEK |