the Marmitek X-10 signals are disturbed by e.g. baby phones which are in TALK mode (continuous transmission). When these kind of signals are present on the power line it is possible that the Marmitek X-10 signals will not come through.

5.The mains do not stop at the front door of your home. Everything that is attached to mains nearby your home can have influence on Marmitek X-10 signals (e.g. heavy machinery). If you think that your system is influenced by devices out of your house, it is advisable to install FD10 Phase Coupler/Filter on each phase entering the house. These filters will block signals coming into or going out of your house, but will also match the impedance for the mains. Hereby make your house Marmitek X-10 compatible for these units. The FD10’s will not only filter but will also couple the phases (please see 1).

INSTRUCTIONS FOR USE

INTRODUCTION

Thank you for buying a Marmitek X-10 UM7206 universal receiver. The UM7206 provides the link between low-voltage appliances and the Marmitek X-10 system. The UM7206 module receives the X-10 signal via the lighting circuit and switches lights and 24 V DC appliances with a current up to 5 A. The UM7206 can be set to pulse or continuous contact and can be controlled remotely with the Marmitek X-10 commands “ON” and “OFF”. The UM7206 is manually operated via two keys: “ON” (on/test) and “OFF”. The UM7206 also has a built-in buzzer that produces a sound when the module receives an “ON” signal. The buzzer can, if preferred be deactivated. If the unit is set to pulse switching with sound, the built-in buzzer will produce three to four high-pitched bleeps. The module is powered and controlled via the 230V lighting circuit and is fitted with a mains power lead.

INSTALLATION

The module is easy to install. Connect the low-voltage appliance to the two potential-free (dead) contacts (screw connectors) and then set the address. After connecting the plug to the mains, the module can be operated both locally and remotely.

1.Using a small screwdriver, set the desired address (e.g. A1).

2.Connect the low-voltage appliance to the screw terminals (max. 24 V DC, 5 A).

3.Activate the UM7206 by connecting the plug to the mains.

4.Adjust the sliding switches to the preferred positions:

Sliding switch Left:

1.Continuous: The module switches on when it receives an ON command, and off when it receives an OFF command.

2.Momentary: The module switches on for 3 - 5 seconds after receiving an ON command and then switches off again.

Sliding switch Right:

1.Sounder Only: Only audio signal.

2.Sounder & Relay: Audio signal and relay contact.

3.Relay Only: Only relay contact.

ENGLISH

UM7206™

5

Image 5
Contents UM7206UM7206 Marmitek HOW does Marmitek X-10 WORK? Universal Receiver Safety WarningsAdresses EnglishKnown devices which can cause attenuation are Signal RangeSliding switch Left InstallationSliding switch Right Instructions for USEFreqently Asked Questions Technical SpecificationsMy modules will not respond to my controller My modules will not react to my remote / sensorEnglish Marmitek WIE Funktioniert Marmitek X-10? Universal Empfänger SicherheitshinweiseAdressierung DeutschWir empfehlen um folgende Geräte zu kontrollieren Reichweite VON SignalenSchiebeschalter links GebrauchsanleitungEinleitung Schiebeschalter rechts Häufig Gestellte FragenWie kommt es, dass einige Module spontan an- oder ausgehen? Meine Module reagieren nicht auf meinen SenderTechnische Daten Marmitek Español Français Récepteur Universe Avertissements DE SecuriteComment Fonctionne LE Système Marmitek X-10? Produits pouvant créer une atténuation Porté DES SignauxFrançais Guide UtilisateurCommutateur coulissant à gauche Données Techniques Foire AUX QuestionsCommutateur coulissant à droite Mes modules ne fonctionnent pas avec mes contrôleursTempérature ambiante Marmitek ¿CÓMO Funciona EL X-10 DE MARMITEK? Avisos DE SeguridadAjuste DE Direcciones EspañolAparatos a controlar Alcance DE LAS SeñalesIntroducción Modo DE EmpleoInstalación Conmutador corredero a la izquierdaDatos Técnicos Preguntas FrecuentesConmutador corredero a la derecha Los módulos no reaccionan al controladorInformación medioambiental para clientes de la Unión Europea Marmitek Come Funziona Marmitek X-10? Precauzioni DI SicurezzaIndirizzi ItalianoPortata DEI Segnali Introduzione InstallazioneIndicazioni PER L’USO Selettore scorrevole a sinistra Domande FrequentiSelettore scorrevole a destra Miei moduli non reagiscono al mio controllerDati Tecnici Marmitek HOE Werkt Marmitek X-10? Universele Ontvanger VeiligheidswaarschuwingenAdressering NederlandsApparatuur die hierbij de moeite waard is om te controleren Bereik VAN SignalenGebruiksaanwijzing InstallatieIntroductie Schuifschakelaar LinksTechnische Gegevens Veel Gestelde VragenHoe komt het dat sommige Modules spontaan aan- of uitgaan? Mijn modules reageren niet op mijn controllerMilieu-informatie voor klanten in de Europese Unie Declaration of Conformity UM7206