2.1.2 Fabricating signal cable S03-75
1.Remove the vinyl sheath by 450 mm.
2.Slide the clamping ring, washer, rubber gasket and washer onto the signal cable in that order.
3.Unravel the outer shield to expose the cores in the outer layer. Then, unravel the inner shield to expose the cores in the inner layer. Label all inner cores to aid in identification.
4.Attach EMI cores to all inner cores and all outer cores, and bind them with cable ties, etc. Note that there are two types of the EMI cores, thick and thin.
5.Trim each core (except coaxial wire) considering its location on the terminal board in the antenna unit.
6.Trim the inner and outer shields leaving 500 mm each. Twist shields together and attach
7.Remove insulation of each core by about 6 mm. Fix
8.Fabricate the coaxial cable. Make the length 10 mm longer than the shield to prevent wire strain. Attach
VINYL SHEATH 450 mm
Inner shield
Under | Cable tie | |
100 mm | ||
|
Outer cores
Inner cores
500mm | Coax cable |
= EMI cores
Outer cores:
Inner cores:
6 mm
Clamping ring
Washers
| |
| |
(Blue, φ 4) |
|
|
Rubber gasket
75 mm
50 mm
6 mm
Fold four times
Figure 2-7 How to ground
signal cable S03-75
Figure 2-6 How to fabricate
signal cable S03-75
45 mm Cut here