4.1.2 Connection of external power supply

An external power supply is necessary when the repeater signal is step-by-step type and the step voltage is below 20 V or output voltage is less than 5 W.

1.Cut the jumper wire JP1 on the GYRO CONVERTER Board when an external power supply is used.

2.Connect the gyro cable and power cable as shown below.

External Power Supply 20 - 135 VAC

20 - 100 VDC

Gyrocompass (Step type)

GYRO CONVERTER Board [A] 64P1106

J5

1R2

2R1/COM

Either connection in case of DC polarity.

S1

J4

1S1

S2

2 S2

 

S3

3 S3

COM

4 T

F.G.

5 F.G.

 

Figure 4-3 Connection of external power supply to GYRO CONVERTER Board

4.1.3 DIP switch, jumper wire settings

Default setting

The default setting of all DIP switches is off and all jumpers wire are set to "#1". (Note that the jumper wire JP1 is set at #1, #2, and #3.) In those settings the gyrocompass having the following characteristics can be directly connected; modification of the GYRO CONVERTER Board is not necessary.

AC synchronous signal: 50/60 Hz

Rotor voltage: 60 to 135 V AC

Stator voltage: 60 to 135 V AC

Gear ratio: 360X

Supply voltage: 30 to 135 V AC

If the specifications of the gyrocompass differ from those mentioned above, change jumper wire and DIP switch settings on the GYRO CONVERTER Board as appropriate. Settings may be changed according to gyrocompass specifications (page 4-4) or make and model of gyrocompass (page 4-5). For the location of DIP switches and jumper wires, see page 4-6.

4-3

Image 42
Contents Marine Radar FR-2115-B/FR-2125-B B . N o . I M E 3 4 8 3 0 H Safety Instructions Radio Frequency Radiation HazardDo not open the equipment Equipment Lists Standard supply System without monitor Optional equipment System Configuration Data SentencesMounting Assembling the antenna unit Fastening the radiator to the radiator bracket Fastening the antenna unit to the mounting platform How to mount the antenna unit Processor Unit Mounting the processor unit Processor unit, inside view Monitor Mounting the monitor Control Unit Antenna Unit Mounting the antenna chassisAntenna unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 2C-2VFabricating the AC power cable Processor UnitFabricating the DC power cable CVV-S 8X2C, option CVV-S 8X2CLeading in cables to the processor unit ANTMonitor Connection of monitor cable inside the monitor Connect the monitor cable inside the monitor as belowControl Unit Power Connectors on the INT Board AC Power Specification of Processor Unit How to attach NH connectorAdjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangConfirming Magnetron Heater Voltage Magnetron heater voltage ratingInitial Setting Menus Press Radar Menu 0 0 0Initial SETTING1 menu Initial SETTING3 menu Installation and connection of the Gyro Converter Board Gyro Converter GC-8INT Board Gyro Converter Board J446 4P J7 5P J465 6P J1 14P Connection of external power supply DIP switch, jumper wire settingsRotor Voltage between R1 & R2 Stator Voltage between S1 & S2 JP1 JP2 JP3 JP4 JP5 Setting the heading readout on the radar display SW1ARP Board ARP-26 ARP board adjustment ARP Board 18P9002BRP Board RP-26 Final check of ARP board10 Processor unit, inside view 11 Processor unit, front view 12 Processor, front and top views Performance Monitor PM-30 Necessary parts PM-30 and OP03-150 Code noAlarm Kit AC-DC Conversion Kit J474 Arpa CPA/TCPA15 Processor unit, inside view Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page