Furuno FR-2115-B installation manual Mounting

Page 9

1. MOUNTING

1.1 Antenna Unit

1.1.1 Mounting considerations

The antenna unit is generally installed either on top of the wheelhouse or on the radar mast, on a suitable platform. Locate the antenna unit where there is a good all-round view.

No funnel, mast or derrick should be within the vertical beamwidth of the antenna in the bow direction, especially zero degrees ±5°, to prevent blind sectors and false echoes on the radar picture.

It is rarely possible to place the antenna unit where a completely clear view in all directions is available. Thus, you should determine the angular width and relative bearing of any shadow sectors for their influence on the radar at the first opportunity after fitting.

Locate the antenna of a direction finder clear of the antenna unit to prevent interference to the direction finder. A separation of more than two meters is recommended.

To lessen the chance of picking up electrical interference, avoid where possible routing the signal cable near other onboard electrical equipment. Also avoid running the cable in parallel with power cables.

A magnetic compass will be affected if placed too close to the antenna unit. Observe the following compass safe distances to prevent deviation of a magnetic compass: Standard compass, 1.70 m (FR-2115-B), 2.10 m (FR-2125-B), Steering compass, 0.90 m (FR-2115-B), 1.20 m (FR-2125-B).

Do not paint the radiator aperture, to ensure proper emission of the radar waves.

The signal cable run between the antenna and the display is available in lengths of 15 m (standard), 20 m, and 30 m. Whatever length is used it must be unbroken; namely, no splicing allowed.

The antenna base is made of cast aluminum. To prevent electrolytic corrosion of the antenna base, use the seal washers and corrosion-proof rubber mat.

Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial performance and hot gases may distort the radiator portion. The antenna unit must not be mounted where the temperature is more than 70°C.

Leave sufficient space around the unit for maintenance and servicing. See the antenna unit outline drawing for recommended maintenance space.

1-1

Image 9
Contents Marine Radar FR-2115-B/FR-2125-B B . N o . I M E 3 4 8 3 0 H Radio Frequency Radiation Hazard Safety InstructionsDo not open the equipment Equipment Lists Standard supply System without monitor Optional equipment Data Sentences System ConfigurationMounting Assembling the antenna unit Fastening the radiator to the radiator bracket Fastening the antenna unit to the mounting platform How to mount the antenna unit Processor Unit Mounting the processor unit Processor unit, inside view Monitor Mounting the monitor Control Unit Mounting the antenna chassis Antenna UnitAntenna unit, front view, cover removed Correct seating of waterproofing gasket 2C-2V Fabricating signal cable S03-75Processor Unit Fabricating the AC power cableCVV-S 8X2C Fabricating the DC power cable CVV-S 8X2C, optionANT Leading in cables to the processor unitMonitor Connect the monitor cable inside the monitor as below Connection of monitor cable inside the monitorControl Unit Power Connectors on the INT Board How to attach NH connector AC Power Specification of Processor UnitAccessing Menus for Initialization and Adjustment Tuning InitializationAdjusting Video Signal Level Restoring default settingsPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING1 menu Initial SETTING3 menu Gyro Converter GC-8 Installation and connection of the Gyro Converter BoardINT Board Gyro Converter Board J446 4P J7 5P J465 6P J1 14P DIP switch, jumper wire settings Connection of external power supplyRotor Voltage between R1 & R2 Stator Voltage between S1 & S2 JP1 JP2 JP3 JP4 JP5 SW1 Setting the heading readout on the radar displayARP Board ARP-26 ARP Board 18P9002B ARP board adjustmentFinal check of ARP board RP Board RP-2610 Processor unit, inside view 11 Processor unit, front view 12 Processor, front and top views Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Alarm Kit J474 Arpa CPA/TCPA AC-DC Conversion Kit15 Processor unit, inside view Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page