How to attach NH connector
HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE
NH connector wire
Shrink tubing
NH connector | 20mm |
housing |
|
1) Insert NH connector | 2) Cut shrink tubing |
wire into NH connector | in 20 mm lengths and |
housing. | slip onto each wire. |
Solder |
|
3) Solder connector | 4) Heat shrink |
to signal cable. | tubing with solder- |
| ing iron. |
Figure 2-15 How to attach NH connector
2.6AC Power Specification of Processor Unit
For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the processor unit as shown in the table below according to ship's mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.
Table
PCB | Power Spec. | Antenna | JP1 | JP2 | JP3 | JP4 | JP91 | JP92 | Power | |
(VAC) | rpm |
| Fuse | |||||||
|
|
|
|
|
|
|
| |||
03P9245A | 100/110/115 | 24 rpm |
| YES | YES | YES | NO | NO | NO | 10A |
03P9245D | 220/230 | 24 rpm |
| NO | NO | NO | YES | NO | NO | 5A |
| PTUBoard |
| Jumper wire to use: |
|
|
|
|
| ||
|
| JP1: 0.8 dia. gilded wire |
|
|
|
| ||||
|
| JP2, JP3, JP4, JP91, JP92: type |
|
JP1
Fuse |
JP2 |
JP92
JP3
JP4
JP91
03P9245
PTU Board