Sterling SSV 05 operating instructions SSV Trouble-shooting Problem Remedy, Test steps

Page 30

SSV 05

5.4. Trouble-shooting

 

Problem

Remedy

The unit is not conveying

 

and is not active

a, b, g, h

The unit is not conveying;

 

the compressed-air valve is switched

 

when the device is switched on

c, f

The unit is not conveying,

 

the compressed air is flowing audibly

c, d, e, f, i, j, k

The unit is overfilled

g, l, m

The unit is not filled properly

c, d, e, f, i, j, k, l

Test steps

 

a)Check whether the unit is switched on.

b)Check whether the mains connector is connected and mains voltage is present.

c)Check whether sufficient compressed air is available.

d)Check whether the injector tube is inserted in the material.

e)Check whether the compressed-air hose is properly connected to the injector tube.

f)Check whether the compressed-air hose is properly connected to the maintenance unit.

g)Check whether the level probe is properly adjusted.

h)Check whether the cable of the level probe is properly connected.

i)Check whether the filter is clogged.

j)Check whether the sieve is clogged.

k)Check whether the conveyor hose is properly connected.

l)Check whether the compressed-air supply is properly adjusted.

SM4-600

Maintenance 29

Image 30
Contents Operating Instructions Single Conveyor Unit SSV Sterling Material ProcessingParts and Service Department Technical service SSV Sterling Material ProcessingTelephone 800 Edition 08/99 SSV Table of contents SSV Technical data Safety instructions Safety instructionsSSV SSV Explanations and information SSV For your safety SSV SSV SSV For the safety of the units Installation instructions SSV General information SSV Installing the conveyor hopper SSV Installing the control and maintenance unit SSV Connecting the compressed-air supply SSV Electrical connection Functional description Control and maintenance unit SSV Method of functioningSet-up Filling level too low Basic setting of the filling level in the conveyor hopperSSV Preparations Filling level too highSet-up Maintenance SSV SSV Maintenance intervals SSV Cleaning/replacing the filter cartridge DisassemblySSV Assembly Adjusting the level probeSSV Trouble-shooting Problem Remedy Test stepsTechnical data SSV Dimension sheet SSV Spare parts list SSV Pos ID-No Designation