Micronics 216 manual Connectors, Pulse Cable Connections

Page 4

For Reflex Mode attach the guide rail (Figure 3) to the pipe as shown below. Turn the locking nut on the fixed transducer anti-clockwise, screwing it down on to the pipe surface. Do not over-tighten , causing the guide rail to lift off the pipe.

Set the separation distance (Figure 3) by sliding the floating transducer along the scale until the front edge of the block is at the recommended distance displayed by the electronics. Now turn the locking nuts on both the floating and the fixed transducers anti-clockwise, until they make finger tight contact with the pipe surface. To mount the transducers in Diagonal Mode, (Figure 4) and the instructions on pages 20-21 of this manual.

Now Press ENTER to read flow. Pressing the appropriate key on the keypad can change flow units. An additional key press will change the timescale of the reading - hr/min/sec.

Figure 3: - Reflex Mode Operation

Separation

Distance

Figure 4:- Diagonal Mode Operation

Separation

Distance

For Diagonal beam mounting follow the sensor mounting instructions on pages 20 and 21 of this manual.

PARTS AND ACCESSORIES

Connectors

There are four sockets on the electronic housing. Two for the transducer cable assemblies (Blue down/Red up), one for the pulse output, one for the PSU/charger unit and one for the optional 4-20mA output. Please specify 4-20mA output in your order so that it can be configured prior to dispatch.

Pulse Cable Connections

Pulse output – Centre (White) positive, Screen (Silver) negative.

4-20 mA Output connections (optional) only added to software versions 216-3 & 216-2

Charger (Use only the charger supplied.)

The charger is supplied with universal plug-in adaptors. When the instrument is charging, but switched off, the display reads ‘CHARGING’. It also displays a battery and plug symbol. CHRG is displayed next to the word ‘Batt’ when in flow mode and the battery charger is connected. When the battery charger is disconnected the display will show a % battery level in the flow mode.

4

Image 4
Contents Portaflow Fast Track Set up Procedure Inverted view of grease applied to sensor block Connectors Pulse Cable ConnectionsKeypad Battery CircuitTransducers Option number for the software Main Menu Switch 0n…Main Menu Quick Start Enter MillimetresAttach Sensors Select Enter and the display will now showError Messages Appear Here Main Menu View/Edit Site DataXXX VIEW/EDIT Site DataDimension Units List SitesSite Number Site NameMain Menu Select Sensor mode Sensor ModeRead Flow Sensor SETMain Menu Set Up Instrument Pulse Output Key EnabledDisplay backlight Application OptionsDelete Key Main Menu Read FlowOptions Key Reset + Total/- Total TotalDamping sec Calibration FactorError Messages Status MessagesTemperature range is -20C to +125C W6 mA OUT OverangeW8 mA Load to High Other MessagesReflex mode Enter a lining thickness firstTransducer Positioning Mounting the TransducersCorrectincorrect Liquid ConditionsPropagation Velocity or Sound Speed Reynolds NumberTo calculate Re use the following formula Application TemperatureMaximum Flow Blue connector downstream Red connector upstreamGull wing and spring attachment Peizo electric crystal Battery Pack EnclosureSupply Voltage OutputsWarranty Liquid Sound Speeds H2OSubstance Form Index Specific Gravity Sound Speed ∆ v/ºC C4H9NO CH2I2C2H3N CH3CO2O C2H6O C2H7NO C2H5IC6H5F C3H8O C3H8OCH4 CH4O C7H9N C7H9N CH4O C7H8KNO3 C7H8O C4H9NO C6H5NO2 CH3NO2 C9H2OC3H8O CF4 C4H9NO C2H6O H2SO4H2O CH4O Charging Controller IC Charging VoltageInstrument differences SoftwareQuicker full charge Examples