Separation Distance

The instrument calculates the separation distance when all parameters have been entered via the keypad. Also the instrument calculates the maximum flow velocity allowed with the standard sensors and indicates whether Reflex or Diagonal mode should be used.

Ultrasonic Couplant

Ultrasonic couplant/grease must be used on the transducer face to interface with the pipe wall.

Fluid Types

Portaflow 216 is capable of measuring clean liquids or oils that have less than 2% by volume of particulate content and air bubbles. During the set up procedure the user is prompted to select from a list of liquids, which include water and oils.

Applications include - river water, seawater, potable water, demin water, treated water, effluent, water/glycol mixes, hydraulic oil, diesel oil and most chemicals.

PROGRAMING-MAIN MENU

Switch 0n

Micronics Ltd.

PORTAFLOW

216-X V1.00

1 for English

Press Enter to start

X – Option number for the software

Main Menu

Press SCROLL up or down to move cursor to the required option and press ENTER to select.

MAIN MENU

Quick start

View/Edit Site Data

Sensor set

Data Logger

Set up RS232

Set up Instrument

Read flow

Main Menu - Quick Start

Selecting quick start offers the user the easiest and quickest option to achieve a flow measurement. If the instrument has already been used, it stores the last application data entered. This allows the user to read flow on the same application without spending time entering new data. Go to ‘Read Flow’ in the main menu.

If QUICK START is selected, proceed with the following routine. Use the scroll keys to select, then press ENTER.

QUICK START

Dimension units?

mm

Inches

6

Image 6
Contents Portaflow Fast Track Set up Procedure Inverted view of grease applied to sensor block Connectors Pulse Cable ConnectionsBattery Circuit KeypadTransducers Switch 0n… Option number for the software Main MenuMain Menu Quick Start Enter MillimetresAttach Sensors Select Enter and the display will now showXXX Error Messages Appear HereMain Menu View/Edit Site Data VIEW/EDIT Site DataSite Number Dimension UnitsList Sites Site NameRead Flow Main Menu Select Sensor modeSensor Mode Sensor SETDisplay backlight Main Menu Set Up Instrument Pulse Output KeyEnabled Application OptionsMain Menu Read Flow Delete KeyOptions Key Damping sec Reset + Total/- TotalTotal Calibration FactorError Messages Status MessagesW8 mA Load to High Temperature range is -20C to +125CW6 mA OUT Overange Other MessagesReflex mode Enter a lining thickness firstTransducer Positioning Mounting the TransducersPropagation Velocity or Sound Speed CorrectincorrectLiquid Conditions Reynolds NumberApplication Temperature To calculate Re use the following formulaMaximum Flow Red connector upstream Blue connector downstreamGull wing and spring attachment Peizo electric crystal Supply Voltage Battery PackEnclosure OutputsWarranty Liquid Sound Speeds H2OSubstance Form Index Specific Gravity Sound Speed ∆ v/ºC C2H3N CH3CO2O C2H6O C2H7NO C4H9NOCH2I2 C2H5ICH4 CH4O C6H5FC3H8O C3H8O C7H9N C7H9N CH4O C7H8C7H8O C4H9NO C6H5NO2 CH3NO2 C9H2O KNO3C3H8O C2H6O H2SO4 CF4 C4H9NOH2O CH4O Instrument differences Charging Controller ICCharging Voltage SoftwareQuicker full charge Examples