Quicker full charge:

The fastest way to fully charge the battery is to charge for 4.5 hrs, then switch the power supply off and on again, thus re-starting the fast charge for another 4.5 hr period, followed by trickle charge.

Warning:

If the battery is getting warm, that would indicate that it is full, and the power supply should not be connected again - overcharging reduces the life of the battery.

Note:

After a recently fully charged battery is connected to the charger, it seems that it takes the MAX712 about 30 min to sense that the battery voltage stops changing, and go to trickle charge.

Examples:

Older PF-300:- A 15 hour charge consists of 4.5 hrs of fast charge (400mA), followed by 10.5 hrs of

trickle charge (50mA): 4.5*0.4+10.5*0.05=2.325Ah=3.5Ah*0.66, which fills the battery to 66% of capacity (3.5Ah).

To fill the remaining 34% at 50mA takes 3.5*0.34/0.05=23.8hrs, +15hrs = 39hrs to 100%. Assuming 20% losses:

(3.5Ah*20%)/50mA=0.7Ah/0.05A=14hrs of trickle charge to cover losses, +39hrs=53hrs total.

In fact it needs ~9hrs * 0.4A = 3.6Ah to fill the battery from empty to 103% full capacity. Assuming 20% losses:

(3.5Ah*20%-0.1)/50mA=0.6Ah/0.05A=12hrs of trickle charge to cover losses, +9hrs=21hrs total. A third session of fast charge would fill the last 17% in 3.5Ah*17%/0.4A=1.5hrs, = 10.5hrs total. Newer PF-300:-

4.5hrs fast: 0.8A*4.5h=3.6Ah = 90% of 4.0Ah

Slow: 10%= 0.4Ah/0.1A = 4h, total 8.5h to 100%

with 20% losses: 0.8Ah/0.1A = 8h

Total time fast and slow: 16.5hrs to 120%.

Fast only: 4.0Ah/0.8A=5hrs, +20%=6hrs,

that needs 2 sessions: 4.5hrs + 1.5hrs to 120%.

PF-SE & 216:- 1.2Ah/0.4A=3hrs to 100% capacity; with 20% losses 3h+20%=3.6hrs total. This is well within the first 4.5hrs.

Micronics Ltd

Knaves Beech Business Centre,

Davies Way, Loudwater, High Wycombe,

Bucks. HP10 9QR

U.K.

Telephone: +44 (0) 1628 810456

Fax: +44 (0) 1628 531540 www.micronicsltd.co.uk

e-mail – sales@micronicsltd.co.uk

31

Image 31
Contents Portaflow Fast Track Set up Procedure Inverted view of grease applied to sensor block Pulse Cable Connections ConnectorsKeypad Battery CircuitTransducers Option number for the software Main Menu Switch 0n…Main Menu Quick Start Millimetres EnterSelect Enter and the display will now show Attach SensorsVIEW/EDIT Site Data Error Messages Appear HereMain Menu View/Edit Site Data XXXSite Name Dimension UnitsList Sites Site NumberSensor SET Main Menu Select Sensor modeSensor Mode Read FlowApplication Options Main Menu Set Up Instrument Pulse Output KeyEnabled Display backlightDelete Key Main Menu Read FlowOptions Key Calibration Factor Reset + Total/- TotalTotal Damping secStatus Messages Error MessagesOther Messages Temperature range is -20C to +125CW6 mA OUT Overange W8 mA Load to HighEnter a lining thickness first Reflex modeMounting the Transducers Transducer PositioningReynolds Number CorrectincorrectLiquid Conditions Propagation Velocity or Sound SpeedTo calculate Re use the following formula Application TemperatureMaximum Flow Blue connector downstream Red connector upstreamGull wing and spring attachment Peizo electric crystal Outputs Battery PackEnclosure Supply VoltageWarranty H2O Liquid Sound SpeedsSubstance Form Index Specific Gravity Sound Speed ∆ v/ºC C2H5I C4H9NOCH2I2 C2H3N CH3CO2O C2H6O C2H7NOC7H9N C7H9N CH4O C7H8 C6H5FC3H8O C3H8O CH4 CH4OKNO3 C7H8O C4H9NO C6H5NO2 CH3NO2 C9H2OC3H8O CF4 C4H9NO C2H6O H2SO4H2O CH4O Software Charging Controller ICCharging Voltage Instrument differencesExamples Quicker full charge