Multiquip GB114BS/BP manual General Information

Page 12

GENERAL INFORMATION

The Multiquip GloBug GB114BS, and GB114BP are general purpose portable glare-free lighting systems. Typical applications for these types of lighting systems include construction sites, emergency road crews and backyard parties.

BALLOON ENVELOPES

The GloBug lighting system can be confi gured with a variety of balloon envelopes (canopy). Please contact the MQ sales department for the balloon of your choice. The GloBug GB114BS and GB114BP shipped from the factory with the drum type balloon.

LIGHTING

Multiquip's GloBug lighting system is comprised of one "Metal Halide" 1000-watt lamp. This lamp has an output of 112,000 lumens.Typical lighting coverage is in excess 150 ft. (46 meters) in a 360 degree pattern.

POWER

These GloBug lighting systems are powered by a portable ballast that can be hand carried. The input power requirements for operating the lighting system is 120 VAC, 60 Hz @ 9.5 amps

GB114BS

The GB114BS lighting system (offset pole) is designed to be attached to a external piece of a equipment such as a paver (Figure 4). This system is equally easy to assemble. Simply attach the supplied support clamps to an external pole or support and you are ready.

GB114BP

When only a complete lamp assembly is required please order Model GB114BP. This model number includes the lamp, protective guard, balloon protective covering and all other components that make up the lamp assemby.

TRANSPORT

The GB114 lighting systems can be transported quite easily. The GB114BP consists of a balloon/lamp, power cable and a ballast, and it has a combined weight of 61 lbs (28 kg). The GB114BS consists a balloon/lamp, power cable, ballast and offset pole, and it has a combined weight of 83 lbs (38 kg).

For ease of service or transport, the lamp assembly is equipped with a quick-disconnect connector that allows the lamp fi xture to be removed quickly. This feature is extremely useful during transport of the lighting system. It is always best to remove the lamp and pack it safely so it will not be damaged.

Figure 4. GB114BS Offset Pole (Paver)

PAGE 12 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)

Image 12
Contents Model GB114BS/BP This Manual Must Accompany the Equipment AT ALL TimesTable of Contents MQ Globug Lighting SystemParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesSafety Symbols General SafetyLighting System Safety Lamp SafetyBalloon Safety  Never attempt service on a running machineGenerator Safety Electrical Safety Always make sure the area above Transporting Safety Loading and UnloadingSpecifications Dimensions GB114BS DimensionsDimensions GB114BP Dimensions GB114BPFootcandle Plot CoverageGeneral Information Page Components Major ComponentsComponents Setup Pole SetupConnecting Power Cable Removing the Protective CoveringApplying Power OperationRaising the Extension Pole Place the ON/OFF switch on the ballast in the on position OPERATION/SHUTDOWNShutdown Removing Lamp Assembly StorageLowering the Extension Pole Fully zip protective cover and fold velcro tab in placeMaintenance Handle KnobInstalling a NEW Lamp I N S TA L L I N G T H E L a M P / BA L L O O N AssemblyReconnect the power cables Replacing the BalloonFilter Replacement Balloon/Lamp PlacementMaintenance Check Points Connector Cable disconnected or loose? Broken? Replace Power Cable Defective or worn cable?Plug Damaged? Replace Lamp Switch Lamp Base Lamp base loose?Troubleshooting Lamp Wiring Diagram BallastPlace the ballast ON/OFF switch in the OFF position Voltage MeasurementsVoltage Measurement Lamp Cable NO- Load Voltage Measurement Lamp Socket NO- LoadVoltage Measurements Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts GB114BP/BS Globug Lighting SystemNameplate and Decals Electrical Shock HazardDCL1001 DCL1002DCL416 DCL417Ballast ASSEMBLY. S/N G30001 A000017700 A100010202A300033800 A200016900Ballast ASSEMBLY. S/N G30002 & Above A000017702 A100015401A200020904 A400079400FAN BLOWER/LAMP Base Assembly A000017600 G30001A000017601 A300033600BALLOON/LAMP Guard Assembly A100028505 3A# A3000602022204220130 1800001000Offset Pole Assembly A000018200 A200019103A200018303 0013512045Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help