SPECIFICATIONS

Table 1. Specifications

GloBug Lighting System

Model

Input Voltage

Ballast

Frequency

Max. Current

Lamp

GB114BS/GB114BP

120 VAC

Magnetic Ballast 60 Hz

60 Hz Single-Phase

9.5 Amps

Lamp Type

1000 Watt Metal Halide

Lumens

112,000

Light Coverage (360°)

150 ft. (45.72 meters)

Surface Temperature (Longitudinal)

476.6°F (247°C) Max.

Surface Temperature (Transversal)

417.2°F (214°C) Max.

Fan Motor

 

Balloon Fan Motor

115 VAC, 60 Hz

Max. Current

.360 Amps

Pressure

31.26 PSI (215.6 kPA)

Balloon

 

Diameter

47.16 in. (1,200 mm)

Material

Heat Resistant Nylon

Heat Resisting Temperature

320 ~ 356°F (160 ~ 180°C)

Melting Temperature

500°F (260°C)

Internal Temperature of Balloon

126°F (52°C) Average

Water Resistance

1,500 mm H20

Weight

 

GB114BS

GB114BP

83 lb. (38 kg)

61 lb. (28 kg)

PAGE 8 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)

Image 8
Contents Model GB114BS/BP This Manual Must Accompany the Equipment AT ALL TimesTable of Contents MQ Globug Lighting SystemParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesSafety Symbols General SafetyLighting System Safety Lamp SafetyBalloon Safety  Never attempt service on a running machine Always make sure the area above Generator SafetyElectrical Safety Transporting Safety Loading and UnloadingSpecifications Dimensions GB114BS DimensionsDimensions GB114BP Dimensions GB114BPFootcandle Plot CoverageGeneral Information Page Components Major ComponentsComponents Setup Pole SetupConnecting Power Cable Removing the Protective CoveringRaising the Extension Pole Applying PowerOperation Shutdown Place the ON/OFF switch on the ballast in the on positionOPERATION/SHUTDOWN Removing Lamp Assembly StorageLowering the Extension Pole Fully zip protective cover and fold velcro tab in placeMaintenance Handle KnobInstalling a NEW Lamp I N S TA L L I N G T H E L a M P / BA L L O O N AssemblyReconnect the power cables Replacing the BalloonFilter Replacement Balloon/Lamp PlacementMaintenance Check Points Connector Cable disconnected or loose? Broken? Replace Power Cable Defective or worn cable?Plug Damaged? Replace Lamp Switch Lamp Base Lamp base loose?Troubleshooting Lamp Wiring Diagram BallastPlace the ballast ON/OFF switch in the OFF position Voltage MeasurementsVoltage Measurement Lamp Cable NO- Load Voltage Measurement Lamp Socket NO- LoadVoltage Measurements Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts GB114BP/BS Globug Lighting SystemNameplate and Decals Electrical Shock HazardDCL1001 DCL1002DCL416 DCL417Ballast ASSEMBLY. S/N G30001 A000017700 A100010202A300033800 A200016900Ballast ASSEMBLY. S/N G30002 & Above A000017702 A100015401A200020904 A400079400FAN BLOWER/LAMP Base Assembly A000017600 G30001A000017601 A300033600BALLOON/LAMP Guard Assembly A100028505 3A# A3000602022204220130 1800001000Offset Pole Assembly A000018200 A200019103A200018303 0013512045Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help