Multiquip GB114BS/BP manual Nameplate and Decals, Electrical Shock Hazard

Page 32
DANGER
ELECTRICAL SHOCK HAZARD
GROUND
To prevent electrical shock or electrocution, the GlowBug MUST be connected to an earth ground. (See NEC Article 250)
DCL427
DCL 1001

NAMEPLATE AND DECALS

3

DANGER

ELECTRICAL

SHOCK HAZARD

When replacing lamp and to prevent electrical shock, ALWAYS shutdown the generator before replacing lamp. Remember to let lamp cool before removing. Use only recommended type lamp as

listed in parts manual.

DCL416

5

 

DANGER

DCL418

VOLTAGE

 

DANGER

To avoid accident or injury

NEVER exceed a travel1 speed of 5 MPH when using

lighting system on a mobile equipment.

4

WARNING

BURN HAZARD

To prevent burns, NEVER touch lamp while lamp is on. Lamp surface gets extremely hot! ALWAYS allow sufficient time for lamp to cool down

before touching.6 DCL417

WARNING

BURN HAZARD

To prevent burns, NEVER touch ballast or cover while lamp is on. These surfaces are extremely hot! ALWAYS allow sufficient time for both surfaces to cool down before touching.

DCL415

DANGER

7

MODEL

SERIAL NO.

2

DANGER

To avoid accident or injury ALWAYS make certain hardware is securely fastened on pipe clamps.

DCL1002

DANGER

To avoid accident or injury ALWAYS make certain hardware is securely fastened on pipe clamps.

DCL1002

2

8

CAUTION

LAMP INFORMATION

ALWAYS turn lamp OFF first, before shutting down generator.

Once lamp is turned OFF, Allow lamp to cool down before turning back on. It will take about 20 minutes before lamp can be turned back on.

DCL409

HIGH

WARNING

 

To avoid injury,

 

you MUST read

 

and understand

 

operator’s manual

15

before using this

machine.

This machine to

be operated by

qualified

 

personnel only.

 

Ask for training

 

as needed.

 

 

ELECTRICAL

 

SHOCK HAZARD

 

NEVER touch a live power cord

 

or active electrical components

 

with wet hands or while standing

14

in water. The possibility of electrical

shock or even death! exists.

 

DCL410

LAMP

13 SWITCH

OFF ON

DCL424

GROUND

12

S1123

CAUTION

LAMP COVER BUZZER

Before operating GlowBug ALWAYS unzip cover, fold into bag on top of balloon and zip.

If the cover has not been removed an audible alarm will sound when power is applied to the GlowBug.

DCL404

9

 

CAUTION

 

COVER

 

INFORMATION

 

Before operating GlowBug

 

ALWAYS unzip cover, fold into

 

bag on top of balloon and zip.

 

Bag Zipper

 

Cover

 

NEVER apply power to the

 

GlowBug until the cover has

11

been inserted inside the bag

B e f o r e s t o r i n g G l o w B u g ,

 

and the balloon is fully exposed.

 

ALWAYS fully cover balloon to

 

prevent damage from dust, dirt

 

and adverse weather conditions.

 

DCL413

10

PAGE 32 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)

Image 32
Contents Model GB114BS/BP This Manual Must Accompany the Equipment AT ALL TimesTable of Contents MQ Globug Lighting SystemParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesSafety Symbols General SafetyLighting System Safety Lamp SafetyBalloon Safety  Never attempt service on a running machine Always make sure the area above Generator SafetyElectrical Safety Transporting Safety Loading and UnloadingSpecifications Dimensions GB114BS DimensionsDimensions GB114BP Dimensions GB114BPFootcandle Plot CoverageGeneral Information Page Components Major ComponentsComponents Setup Pole SetupConnecting Power Cable Removing the Protective CoveringRaising the Extension Pole Applying PowerOperation Shutdown Place the ON/OFF switch on the ballast in the on positionOPERATION/SHUTDOWN Removing Lamp Assembly StorageLowering the Extension Pole Fully zip protective cover and fold velcro tab in placeMaintenance Handle KnobInstalling a NEW Lamp I N S TA L L I N G T H E L a M P / BA L L O O N AssemblyReconnect the power cables Replacing the BalloonFilter Replacement Balloon/Lamp PlacementMaintenance Check Points Connector Cable disconnected or loose? Broken? Replace Power Cable Defective or worn cable?Plug Damaged? Replace Lamp Switch Lamp Base Lamp base loose?Troubleshooting Lamp Wiring Diagram BallastPlace the ballast ON/OFF switch in the OFF position Voltage MeasurementsVoltage Measurement Lamp Cable NO- Load Voltage Measurement Lamp Socket NO- LoadVoltage Measurements Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts GB114BP/BS Globug Lighting SystemNameplate and Decals Electrical Shock HazardDCL1001 DCL1002DCL416 DCL417Ballast ASSEMBLY. S/N G30001 A000017700 A100010202A300033800 A200016900Ballast ASSEMBLY. S/N G30002 & Above A000017702 A100015401A200020904 A400079400FAN BLOWER/LAMP Base Assembly A000017600 G30001A000017601 A300033600BALLOON/LAMP Guard Assembly A100028505 3A# A3000602022204220130 1800001000Offset Pole Assembly A000018200 A200019103A200018303 0013512045Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help