Multiquip GB114BS/BP manual Operation, Raising the Extension Pole, Applying Power

Page 18

OPERATION

RAISING THE EXTENSION POLE

1.Before raising the extension pole, make sure the T-handle bolt lock (Figure 6-O) is securely tightened. This will prevent the balloon/lamp assembly from falling off. In addition make sure that the lamp power cable is connected to the mating end of the power source cable.

2.Raise extension pole (Figure 6-L) to desired height. Watch out for any overhead obstructions.

3.Using 19 mm wrench, tighten extension clamp bolt (Figure 6-Q) securely. Keep wrench in a safe place where it will not get lost.

DANGER

ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, Serious

Injury or Death!

DANGER

When raising the extension pole, ALWAYS be on the lookout for overhead obstructions such as high voltage power lines. The possibility exists of electrocution, even death! if the lighting system comes in contact with high voltage power lines.

APPLYING POWER

1.Make sure the power ON/OFF switch (Figure 10) located near the bottom of the ballast is in the OFF position.

ON/OFF

BALLAST

SWITCH

 

OFF

Figure 10. Power OFF/ON Switch (Off Positon)

2.If using a power source (Figure 11) other than a portable generator, plug the AC power cord from the ballast into a 120 VAC, 60 Hz receptacle that is protected by a at least a 15 amp circuit breaker.

CONNECT

 

TO BALLOON

BALLAST

POWER

CABLE

 

EXTERNAL

SINGLE-PHASE

(120 VAC)

POWER SOURCE

AC POWER

CORD

RECEPTACLE

Figure 11. Applying 120 VAC Power

NOTICE

If using a portable generator, start the generator as referenced in the "Start-up Section" of the supplied generator manual.

Once the generator has started, plug the AC power cord from the ballast (Figure 11) into a GFCI receptacle on the generator.

PAGE 18 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)

Image 18
Contents Model GB114BS/BP This Manual Must Accompany the Equipment AT ALL TimesTable of Contents MQ Globug Lighting SystemParts Ordering Procedures Ordering parts has never been easierSafety Symbols Safety InformationSafety Messages General SafetyBalloon Safety Lighting System SafetyLamp Safety  Never attempt service on a running machineGenerator Safety Electrical Safety Always make sure the area above Transporting Safety Loading and UnloadingSpecifications Dimensions GB114BS DimensionsDimensions GB114BP Dimensions GB114BPFootcandle Plot CoverageGeneral Information Page Components Major ComponentsComponents Setup Pole SetupConnecting Power Cable Removing the Protective CoveringApplying Power OperationRaising the Extension Pole Place the ON/OFF switch on the ballast in the on position OPERATION/SHUTDOWNShutdown Lowering the Extension Pole Removing Lamp AssemblyStorage Fully zip protective cover and fold velcro tab in placeMaintenance Handle KnobReconnect the power cables Installing a NEW LampI N S TA L L I N G T H E L a M P / BA L L O O N Assembly Replacing the BalloonFilter Replacement Balloon/Lamp PlacementMaintenance Check Points Plug Damaged? Replace Lamp Switch Connector Cable disconnected or loose?Broken? Replace Power Cable Defective or worn cable? Lamp Base Lamp base loose?Troubleshooting Lamp Wiring Diagram BallastVoltage Measurement Lamp Cable NO- Load Place the ballast ON/OFF switch in the OFF positionVoltage Measurements Voltage Measurement Lamp Socket NO- LoadVoltage Measurements Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts GB114BP/BS Globug Lighting SystemNameplate and Decals Electrical Shock HazardDCL416 DCL1001DCL1002 DCL417Ballast ASSEMBLY. S/N G30001 A300033800 A000017700A100010202 A200016900Ballast ASSEMBLY. S/N G30002 & Above A200020904 A000017702A100015401 A400079400FAN BLOWER/LAMP Base Assembly A000017601 A000017600G30001 A300033600BALLOON/LAMP Guard Assembly 2204220130 A1000285053A# A300060202 1800001000Offset Pole Assembly A200018303 A000018200A200019103 0013512045Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help