4.4Fabricating Cable, Assembling Connectors
Fabricating cable
L
Shield
Vinyl sheath
45Anticorrosive
40sheath
L = 250
Armor | L = 470 | ||
440 | |||
|
Core
Insulating tape
Expose cores, and then wind shield around the armor.
Figure 4-4 Fabrication cable 00-8016-038-313-761HV
Assembling the 38P connector
Shorten the unused wires appropriately and their ends with vinyl tape to prevent short circuit.
Guide Pin A | Guide Pin B |
|
| Position No. |
| |
Insulate unused wires | Guide Pin A | Guide Pin B | |
with vinyl tape. | |||
(Large) | (Small) | ||
|
Figure 4-5 How to assemble the 38P connector
Positioning guide pins
Guide pins of the connector identify the mating receptacle. Position them as shown below. Table
Connector | J201 | Positioning Tool | ||
Guide Pin |
|
|
|
|
|
|
|
|
|
Guide Pin A (Large) | 1 | 5 | 1 |
|
|
|
|
| Type: |
Guide Pin B (Small) | 1 | 1 | 1 | |
|
|
|
|
|
15