4.5 Connection of Transducer Cables
The transducer cables are supplied with connectors. Plug them into the receptacles in the re- ceiver unit, referring to the stickers on the cables.
Figure 4-23 Receiver unit, rear view
Lead the cable into the receiver unit and clamp it as follows.
Ground the cable by cable clamp.
Vinyl tape
1. Use the connector puller (supplied) to unplug connectors.
Connector Puller
(Code No.
2.When one or some of the lead wires are severed near a connector, cut off all lead wires connected to the connector and solder the "XH connector assembly" (type
23