Furuno CSH-23F, CSH-24F manual LC fixing position priority

Page 46

LC fixing position priority

Latitude and Longitude are set to LC with S3 on the DIP switch DP-1.

1.LC-RMA from NMEA

2.LC-RMA from CI/NMEA

3.<24> from CIF port

Depth priority

Depth is set to CIF/NMEA with S5 on the DIP switch DP-1.

1.SD-DPT from NMEA port

2.SD-DPT from CI/NMEA port

3.SD-DBT from NMEA port

4.SD-DBT from CI/NMEA port

5.<57> from CIF port

Ship’s movement data priority (data from GPS/DR)

Ship’s movement data is set to GPS·DR with S1/S2 on the DIP switch DP-1

1.GP-VTC from NMEA port

2.GP-VTC from CI/NMEA port

3.GP-RMC from NMEA port

4.GP-RMC from CI/NMEA port

5.<48> from CIF port

6.<41> from CIF port

Ship’s movement data priority (data from Current indicator)

Ship’s movement data is set to Current indicator with S1/S2 on the DIP switch DP-1

1.VD-VTG from NMEA port

2.VD-VTG from CI/NMEA port

3.VD-VHW from NMEA port

4.VD-VHW from CI/NMEA port

5.CIF signal <66> from CI/NMEA port

6.<66> from CIF port

Ship’s movement data priority (data from Gyro/Navigation)

Ship’s movement data is set to Gyrocompass/navigation with S1/S2 on the DIP switch DP-1.

1.GP-VTG from NMEA port

2.GP-VTG from CI/NMEA port

3.GP-RMC from NMEA port

4.GP-RMC from CI/NMEA port

5.LC-VTG NMEA port

6.LC-VTG from CI/NMEA port

7.LC-RMA from NMEA port

8.LC-RMA from CI/NMEA port

9.<48> from CIF port

10.<44> from CIF port

Current data (Multi layer) priority

1.VD-CUR from NMEA port

2.VD-CUR from CI/NMEA port

3.CIF signal <76> from CI/NMEA port

4.<76> from CIF port

Current data (single layer) priority

1.VD-VDR from NMEA port

2.VD-VDR from CI/NMEA port

3.CIF signal <56> from CI/NMEA port

4.<56> from CIF port

41

Image 46
Contents Color Scanning Sonar 00080806903 Safety Instructions Table of Contents System Configuration Equipment Lists Optional Equipment Mounting the Hull Unit and Receiver Unit Location of hull unitMaintenance space, example sonar compartment Installation Method Xdcr Travel Shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unitInstalling stays anti-vibration measure Fastening receiver unit to hull unitMounting the Display Unit/Sub-display Unit Mounting the display unit/sub-display unitMounting the Interface Unit Mounting the Transmitter UnitMounting the FNZ Joint Box Grounding the Equipment 12 Location of ground terminals on equipmentWiring Cable ConfigurationHow to Use the Crimping Tool, Pin Extractor How to use the crimping tool How to use the pin extractorConnectors LocationFabricating Cable, Assembling Connectors Assembling connector NSC-253P CN-A15 Clamping the cableAssembling 38P connector Fabricating cable 54-038-000-601/SC CN-E1Fabricating cable 10S1259 connected terminal board TB-E1 Fabricating cable DPYCY-4connected to terminal board TB-E1Fabricating cable 54-038-000-601/SC CN-B2, CN-B3, CN-B4 14 Fabricating cable 54-038-000-601/SCFabricating cable 10S1259 connected to terminal board TB-B1 16 Clamping the cable19 Assembling 38P connector 22 Fabricating cable 10S1259 Connection of Transducer Cables 23 Receiver unit, rear viewConnection of Interface Unit CS-120A Connections for true motion and target lockSpeed pulse signal Connections for ES picture and FNZ markers Wiring Data Data SourceFabrication, assembling 10P and 7P connectors Connection of Sub-display Unit CSH-236/236F Option DIP switch settingConnections Synchronizing Transmission with Other Sonars, Echo Sounders ConnectionsMenu setting Interlocking Operation with Other Sonar Connections for interlocking functionsConnections for interlocking remote control 37 Connections for interlocking remote controlChanging Power Specifications Adjustment and Check Hull Unit CheckHeading Adjustment Init SET/TEST MenuDIP Switch Setting in the Display Unit Setting and Adjustment of the Interface Unit CS-120A DIP switch settingInterface unit 10P0047 adjustment OFFAdjustment of signal level R36, R56 Priority for dataLC fixing position priority Mounting procedure Processor Unit CSH-235/235F Blackbox Type for CSH-23/23FConnectors for Monitor Protective earthProcessor unit right side, cover removed Packing List Spare Parts List for 工事材料表 Page Page 000-070-208 10CJ-X-9302 000-070-209 10CJ-X-9303 Furuno Electric CO .,LTD Installation Materials Name Outline Hole Plug Page 006-959-800-00 10CC-X-9401 Panel Screw アイボルト 受信装置用 For Power Supply Unit アース板 電源装置用 006-030-650-00 10CJ-X-9402 For Transceiver Unit 貼りマーク 送信装置工材 コンタクト ピン(8017 電源装置工材 Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Dec Page Page Page Page Page Page Page Color Scanning Sonar Page Color Scanning Sonar Processor Unit Interface Unit