Hoshizaki 73180 service manual Priming Instructions

Page 31

5)If water pumps out properly and DP then de-energizes, proceed to step 6. If water does not pump out properly and/or DP does not de-energize, follow the steps below to prime DP.

Priming Instructions

a.Disconnect the icemaker's power cord from the electrical outlet, then reconnect to the electrical outlet. WARNING! To reduce the risk of electric shock, do not touch the power cord with damp hands.

b.Slowly pour another 16 to 24 oz. (500 to 750 ml) of water over the storage bin drain hole in the storage bin. If not already energized, DP should energize.

c.Confirm that water is discharged through the discharge hose. DP should then

de‑energize. If not, repeat steps a through c until water is discharged through the discharge hose and DP de‑energizes. DP is primed when DP de-energizes.

d. If water now pumps out properly and DP de-energizes, proceed to step 6. If water still does not pump out properly and/or DP does not de‑energize, follow the steps in "IV.E.3. Float Switch Cleaning" before proceeding.

6)Move the power switch to the "ON" position.

7)Pour another 16 to 24 oz. (500 to 750 ml) of water into the icemaker's ice storage bin, then completely restrict the discharge hose while DP is operating. See Fig. 7. Pour more water into the icemaker's ice storage bin until the icemaker turns off. DP will continue to operate. Check for leaks.

8)Remove the discharge hose restriction and allow the water to be pumped out normally. Power to the icemaker will be restored when the water in DP returns to a normal level.

9)If the icemaker fails to turn off with the discharge hose restricted or the pump fails to pump out the water, follow the steps in "IV.E.3. Float Switch Cleaning".

Legend: DP–drain pump

Upper Rear Panel

Vent Hose

Discharge Hose

Lower Rear Panel

Fig. 7

31

Image 31
Contents 100BAF-DS 100BAF-AD 100BAF-ADDS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Auxiliary Codes A-1 and Earlier Specifications 100BAFAuxiliary Codes A-2 and Later 100BAF-DS 100BAF-DS, 2. Auxiliary Codes A-2 and Later 100BAF-AD 100BAF-AD, 2. Auxiliary Codes A-2 and Later 100BAF-ADDS 100BAF-ADDS, 2. Auxiliary Codes A-2 and Later Auxiliary Codes II. General Information ConstructionFront Auxiliary Codes RearIcemaking Unit Freeze Cycle Sequence of OperationFill Cycle Auxiliary Codes A-1 and Earlier Auxiliary Codes A-2 and Later Auxiliary Codes A-2 and Later Wiring DiagramIcemaker with Optional Drain Pump HS-0248 100BAF Series Performance DataDiagnostic Procedure IV. Service DiagnosisIce Production Check Page Auxiliary Codes A-2 and Later Bin Control Check Float Switch Check Lower Float white Plastic Retainer Clip Float Switch CleaningOverview Optional Drain Pump HS-0248Drain Pump Check Priming Instructions Float Switch Cleaning No Ice Production Possible Cause Startup Diagnostic ChartsShutdown Fill Cycle and Refill Cycle Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-134a BrazingComponent Important Notes for Component ReplacementRemoval and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of Extruding Head Removal and Replacement of Auger Removal and Replacement of Evaporator Page 5b. Lower Housing Page VI. Maintenance Frequency Area Task Maintenance ScheduleCleaning Solution Cleaning and Sanitizing InstructionsPage Sanitizing Solution Page Cleaning Solution Page Sanitizing Solution Storage Bin Drain Condenser Auxiliary Codes A-1 and Earlier Skip to step VII. Preparing the Icemaker for Periods of Non-UseVIII. Disposal