Hoshizaki 73180 service manual 100BAF-AD

Page 11

C. C-100BAF-AD

1. Auxiliary Codes A-1 and Earlier

AC SUPPLY VOLTAGE

115/60/1

 

 

 

 

 

AMPERAGE

4.0 A

 

 

 

 

 

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

 

 

 

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

 

50

 

70

90

lbs./day ( kg/day )

70

 

 

*92 (42)

 

89 (40)

84 (38)

Reference without *marks

80

 

 

81 (37)

 

71 (32)

66 (30)

 

90

 

 

66 (30)

 

*62 (28)

57 (26)

SHAPE OF ICE

100

 

 

55 (25)

 

54 (24)

*49 (22)

Cubelet

 

 

 

 

 

 

ICE QUALITY

Approx. 90%

 

 

 

 

APPROXIMATE STORAGE CAPACITY

29 lbs.

(13 kg)

[Bin Control Setting 22 lbs. (10.0 kg)]

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

 

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

310 (12.1)

 

 

297 (7.7)

 

WATER gal./24HR (gal./100 lbs.)

7.7 (12)

 

 

 

11.1 (12)

 

EXTERIOR DIMENSIONS (WxDxH)

14.9" x 22.6" x 31.5"

 

(378 x 575 x 800mm)

EXTERIOR FINISH

Stainless steel, Galvanized Steel (Rear)

 

WEIGHT

Net 104 lbs. ( 47 kg ), Shipping 115 lbs. (52 kg) without pallet

CONNECTIONS - ELECTRIC

Cord Connection

 

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

- DRAIN

Outlet

1/2" FPT

 

 

 

 

ICE MAKING SYSTEM

Auger type

 

 

 

 

HARVESTING SYSTEM

Direct Drive Auger (80W Gear Motor)

 

ICE MAKING WATER CONTROL

Mechanical float valve

 

 

 

COOLING WATER CONTROL

N/A

 

 

 

 

 

 

BIN CONTROL SYSTEM

Thermostat

 

 

 

 

COMPRESSOR

Hermetic, Model QA51K13GAU6

 

CONDENSER

Air-cooled, Fin and tube type

 

EVAPORATOR

Copper Tube on Cylinder

 

 

 

REFRIGERANT CONTROL

Capillary Tube

 

 

 

 

REFRIGERANT CHARGE

R134a

3.17 oz.

(90 g)

 

 

 

DESIGN PRESSURE

High 240 PSIG, Low 120 PSIG

 

P.C. BOARD CIRCUIT PROTECTION

N/A

 

 

 

 

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector

 

GEAR MOTOR PROTECTION

Manual reset Circuit Breaker

 

 

 

LOW WATER PROTECTION

Suction Temperature Safety

 

 

 

ACCESSORIES - SUPPLIED

Ice Scoop; pump adapter hose

 

- REQUIRED

N/A

 

 

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

104 - 127 V

 

AMBIENT TEMP.

 

 

45 - 100° F

 

WATER SUPPLY TEMP.

 

 

45 - 90° F

 

WATER SUPPLY PRESSURE

7 - 113 PSIG

AGENCY

UL OUTDOOR APPROVED, cUL

 

 

ETL

 

 

 

 

 

 

Note: We reserve the right to make changes in specifications

and design without prior

notice.

 

 

 

 

 

 

 

11

Image 11
Contents 100BAF-DS 100BAF-AD 100BAF-ADDS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Auxiliary Codes A-1 and Earlier Specifications 100BAFAuxiliary Codes A-2 and Later 100BAF-DS 100BAF-DS, 2. Auxiliary Codes A-2 and Later 100BAF-AD 100BAF-AD, 2. Auxiliary Codes A-2 and Later 100BAF-ADDS 100BAF-ADDS, 2. Auxiliary Codes A-2 and Later Auxiliary Codes II. General Information ConstructionFront Auxiliary Codes RearIcemaking Unit Freeze Cycle Sequence of OperationFill Cycle Auxiliary Codes A-1 and Earlier Auxiliary Codes A-2 and Later Auxiliary Codes A-2 and Later Wiring DiagramIcemaker with Optional Drain Pump HS-0248 100BAF Series Performance DataIce Production Check IV. Service DiagnosisDiagnostic Procedure Page Auxiliary Codes A-2 and Later Bin Control Check Float Switch Check Lower Float white Plastic Retainer Clip Float Switch CleaningDrain Pump Check Optional Drain Pump HS-0248Overview Priming Instructions Float Switch Cleaning No Ice Production Possible Cause Startup Diagnostic ChartsShutdown Fill Cycle and Refill Cycle Shutdown Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-134a BrazingComponent Important Notes for Component ReplacementRemoval and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of Extruding Head Removal and Replacement of Auger Removal and Replacement of Evaporator Page 5b. Lower Housing Page VI. Maintenance Frequency Area Task Maintenance ScheduleCleaning Solution Cleaning and Sanitizing InstructionsPage Sanitizing Solution Page Cleaning Solution Page Sanitizing Solution Storage Bin Drain Condenser Auxiliary Codes A-1 and Earlier Skip to step VII. Preparing the Icemaker for Periods of Non-UseVIII. Disposal