Hoshizaki 73180 service manual Fill Cycle and Refill Cycle

Page 35

2. Auxiliary Codes A-2 and Later

No Ice Production - Possible Cause

 

Startup

 

 

1. Power Supply

a) Unplugged, off, blown fuse, or tripped breaker.

 

 

 

b) Not within specifications.

2. Power Switch

a) "OFF" position.

 

 

 

b) Bad contacts.

 

 

3. Bin Control Thermostat Assembly

a) Open with bin filled with ice.

(with integrated heater)

 

b) Ambient temperature too cool.

 

 

c) Out of position.

 

 

 

d) Out of adjustment. See "IV.C. Bin Control Check."

 

 

 

e) Bad contacts.

 

 

 

f) Bad thermostat heater.

4. Optional Drain Pump HS-0248

a) Drain pump's upper float switch closed.

Safety

 

 

 

 

Fill Cycle and Refill Cycle

 

 

1. Water Supply

a) Water supply off or improper water pressure.

 

 

 

b) External water filters clogged.

2. Water Control Relay

a) Energized and not allowing water valve to energize.

 

b) Defective.

 

 

3. Inlet Water Valve

a) Screen or orifice clogged.

 

 

 

b) Coil winding open.

 

 

4. Float Switch

a) Float does not move freely.

See "IV.D. Float Switch Check

b) Defective.

and Cleaning"

 

 

Freeze Cycle

 

 

1. Water Control Relay

a) Open.

 

 

2. Time Delay Relay

a) Defective.

 

 

3. Gear Motor

a) Gear motor external protector (2.4~3.0A) tripped.

 

b) Gear motor internal protector open or windings open.

 

 

 

c) Bad gear motor capacitor.

 

 

 

d) Locked bearings.

 

 

 

e) Spline coupling or gear broken and auger not turning.

4. Fan Motor

a) Motor winding open.

 

 

 

b) Bearing worn out or locked rotor.

 

 

 

c) Fan blade does not move freely.

 

 

5. Compressor Relay

a) Open coil.

 

b) Open contacts.

 

 

6. Compressor

a) Compressor external protector open or defective.

 

 

 

b) Motor winding open.

 

 

 

c) PTC relay contacts bad or coil winding open.

 

d) Inefficient.

 

 

7. Evaporator

a) Dirty.

 

 

 

b) Damaged or defective.

 

 

8. Condenser

a) Dirty.

35

Image 35
Contents 100BAF-DS 100BAF-AD 100BAF-ADDS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Auxiliary Codes A-1 and Earlier Specifications 100BAFAuxiliary Codes A-2 and Later 100BAF-DS 100BAF-DS, 2. Auxiliary Codes A-2 and Later 100BAF-AD 100BAF-AD, 2. Auxiliary Codes A-2 and Later 100BAF-ADDS 100BAF-ADDS, 2. Auxiliary Codes A-2 and Later Auxiliary Codes II. General Information ConstructionFront Auxiliary Codes RearIcemaking Unit Freeze Cycle Sequence of OperationFill Cycle Auxiliary Codes A-1 and Earlier Auxiliary Codes A-2 and Later Auxiliary Codes A-2 and Later Wiring DiagramIcemaker with Optional Drain Pump HS-0248 100BAF Series Performance DataIce Production Check IV. Service DiagnosisDiagnostic Procedure Page Auxiliary Codes A-2 and Later Bin Control Check Float Switch Check Lower Float white Plastic Retainer Clip Float Switch CleaningDrain Pump Check Optional Drain Pump HS-0248Overview Priming Instructions Float Switch Cleaning No Ice Production Possible Cause Startup Diagnostic ChartsShutdown Fill Cycle and Refill Cycle Shutdown Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-134a BrazingComponent Important Notes for Component ReplacementRemoval and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of Extruding Head Removal and Replacement of Auger Removal and Replacement of Evaporator Page 5b. Lower Housing Page VI. Maintenance Frequency Area Task Maintenance ScheduleCleaning Solution Cleaning and Sanitizing InstructionsPage Sanitizing Solution Page Cleaning Solution Page Sanitizing Solution Storage Bin Drain Condenser Auxiliary Codes A-1 and Earlier Skip to step VII. Preparing the Icemaker for Periods of Non-UseVIII. Disposal