2. Auxiliary Codes A-2 and Later

AC SUPPLY VOLTAGE

115/60/1

 

 

 

 

 

AMPERAGE

4.0 A

 

 

 

 

 

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

 

 

 

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

 

50

 

70

90

lbs./day ( kg/day )

70

 

 

*92 (42)

 

89 (40)

84 (38)

Reference without *marks

80

 

 

81 (37)

 

71 (32)

66 (30)

 

90

 

 

66 (30)

 

*62 (28)

57 (26)

SHAPE OF ICE

100

 

 

55 (25)

 

54 (24)

*49 (22)

Cubelet

 

 

 

 

 

 

ICE QUALITY

Approx. 90%

 

 

 

 

APPROXIMATE STORAGE CAPACITY

29 lbs.

(13 kg)

[Bin Control Setting 22 lbs. (10.0 kg)]

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

 

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

310 (12.1)

 

 

297 (7.7)

 

WATER gal./24HR (gal./100 lbs.)

7.7 (12)

 

 

 

11.1 (12)

 

EXTERIOR DIMENSIONS (WxDxH)

14.9" x 22.6" x 33.5"

 

(378 x 575 x 850mm)

EXTERIOR FINISH

Stainless steel, Galvanized Steel (Rear)

 

WEIGHT

Net 108 lbs. ( 49 kg ), Shipping 120 lbs. (54 kg)

 

CONNECTIONS - ELECTRIC

Cord Connection

 

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

 

- DRAIN

Outlet

1/2" FPT

 

 

 

 

ICE MAKING SYSTEM

Auger type

 

 

 

 

HARVESTING SYSTEM

Direct Drive Auger (80W Gear Motor)

 

ICE MAKING WATER CONTROL

Float Switch

 

 

 

 

COOLING WATER CONTROL

N/A

 

 

 

 

 

 

BIN CONTROL SYSTEM

Thermostat

 

 

 

 

COMPRESSOR

Hermetic, Model QA51K13GAU6

 

CONDENSER

Air-cooled, Fin and tube type

 

 

 

EVAPORATOR

Copper Tube on Cylinder

 

 

 

REFRIGERANT CONTROL

Capillary Tube

 

 

 

 

REFRIGERANT CHARGE

R134a

3.17 oz.

(90 g)

 

 

 

DESIGN PRESSURE

High 240 PSIG, Low 120 PSIG

 

P.C. BOARD CIRCUIT PROTECTION

N/A

 

 

 

 

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector

 

GEAR MOTOR PROTECTION

Manual reset Circuit Breaker

 

 

 

LOW WATER PROTECTION

Float Switch and Timer

 

 

 

ACCESSORIES - SUPPLIED

Ice Scoop; Drain Pump Adapter Hose

 

- REQUIRED

N/A

 

 

 

 

 

 

- OPTION

Drain Pump

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

104 - 127 V

 

AMBIENT TEMP.

 

 

45 - 100° F

 

WATER SUPPLY TEMP.

 

 

45 - 90° F

 

WATER SUPPLY PRESSURE

7 - 113 PSIG

AGENCY

UL OUTDOOR APPROVED, cUL

 

 

ETL

 

 

 

 

 

 

Note: We reserve the right to make changes in specifications

and design without prior

notice.

 

 

 

 

 

 

 

8

Image 8
Contents 100BAF-DS 100BAF-AD 100BAF-ADDS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Specifications 100BAF Auxiliary Codes A-1 and EarlierAuxiliary Codes A-2 and Later 100BAF-DS 100BAF-DS, 2. Auxiliary Codes A-2 and Later 100BAF-AD 100BAF-AD, 2. Auxiliary Codes A-2 and Later 100BAF-ADDS 100BAF-ADDS, 2. Auxiliary Codes A-2 and Later II. General Information Construction FrontAuxiliary Codes Rear Auxiliary CodesIcemaking Unit Sequence of Operation Freeze CycleFill Cycle Auxiliary Codes A-1 and Earlier Auxiliary Codes A-2 and Later Wiring Diagram Auxiliary Codes A-2 and LaterIcemaker with Optional Drain Pump HS-0248 Performance Data 100BAF SeriesIce Production Check IV. Service DiagnosisDiagnostic Procedure Page Auxiliary Codes A-2 and Later Bin Control Check Float Switch Check Float Switch Cleaning Lower Float white Plastic Retainer ClipDrain Pump Check Optional Drain Pump HS-0248Overview Priming Instructions Float Switch Cleaning Diagnostic Charts No Ice Production Possible Cause StartupShutdown Fill Cycle and Refill Cycle Shutdown Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Brazing Evacuation and Recharge R-134aImportant Notes for Component Replacement ComponentRemoval and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of Extruding Head Removal and Replacement of Auger Removal and Replacement of Evaporator Page 5b. Lower Housing Page VI. Maintenance Maintenance Schedule Frequency Area TaskCleaning and Sanitizing Instructions Cleaning SolutionPage Sanitizing Solution Page Cleaning Solution Page Sanitizing Solution Storage Bin Drain Condenser VII. Preparing the Icemaker for Periods of Non-Use Auxiliary Codes A-1 and Earlier Skip to stepVIII. Disposal