Hoshizaki 73180 service manual Condenser

Page 58

D. Condenser

Check the condenser once a year, and clean if required by following the steps below. More frequent cleaning may be required depending on location.

WARNING

Move the power switch to the "OFF" position, then unplug the unit from the electrical outlet before cleaning the condenser.

To reduce the risk of electric shock, do not touch the power switch or plug with damp hands.

Condenser fins are sharp. Use care when cleaning.

1)Move the power switch to the "OFF" position, then unplug the unit from the electrical outlet.

2)Remove the 2 screws securing the front panel, then remove the panel. See Fig. 17.

3)Remove the 2 screws securing the louver, then remove the louver.

4)Use a brush attachment on a vacuum cleaner to gently clean the condenser fins. Do not use too much force, otherwise the fins could be damaged.

5)Replace the louver and front panel in their correct positions. Ensure that the screws are securely in place.

6)Plug the unit back in. Move the power switch to the "ON" position to start the automatic icemaking process.

Condenser

Front Panel

Fig. 17

Louver

Screws

Screws

58

Image 58
Contents 100BAF-DS 100BAF-AD 100BAF-ADDS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Specifications 100BAF Auxiliary Codes A-1 and EarlierAuxiliary Codes A-2 and Later 100BAF-DS 100BAF-DS, 2. Auxiliary Codes A-2 and Later 100BAF-AD 100BAF-AD, 2. Auxiliary Codes A-2 and Later 100BAF-ADDS 100BAF-ADDS, 2. Auxiliary Codes A-2 and Later Auxiliary Codes Rear II. General Information ConstructionFront Auxiliary CodesIcemaking Unit Sequence of Operation Freeze CycleFill Cycle Auxiliary Codes A-1 and Earlier Auxiliary Codes A-2 and Later Wiring Diagram Auxiliary Codes A-2 and LaterIcemaker with Optional Drain Pump HS-0248 Performance Data 100BAF SeriesDiagnostic Procedure IV. Service DiagnosisIce Production Check Page Auxiliary Codes A-2 and Later Bin Control Check Float Switch Check Float Switch Cleaning Lower Float white Plastic Retainer ClipOverview Optional Drain Pump HS-0248Drain Pump Check Priming Instructions Float Switch Cleaning Diagnostic Charts No Ice Production Possible Cause StartupShutdown Fill Cycle and Refill Cycle Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-134aImportant Notes for Component Replacement ComponentRemoval and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of Extruding Head Removal and Replacement of Auger Removal and Replacement of Evaporator Page 5b. Lower Housing Page VI. Maintenance Maintenance Schedule Frequency Area TaskCleaning and Sanitizing Instructions Cleaning SolutionPage Sanitizing Solution Page Cleaning Solution Page Sanitizing Solution Storage Bin Drain Condenser VII. Preparing the Icemaker for Periods of Non-Use Auxiliary Codes A-1 and Earlier Skip to stepVIII. Disposal