Solid State Logic 82S6PC1010C manual MicAmp Card SSL ref, Analogue input/output Card SSL ref

Page 37

Section 5

 

Installation Wiring

 

 

 

 

I/O – MicAmp Card (SSL ref. 908)

Each MicAmp Input Card contains 12 Microphone circuits. The inputs are accessed via a Varicon (aka. EDAC or Elco) 56-way female connector.

The split outputs are accessed via two 25-pin D-type female connectors. Refer to Appendix C for the connector pinouts.

SSL is able to supply mating connectors if requested, (at additional cost).

If more than one micamp card is fitted then the card furthest to the right will have the lowest input number and the channel number s will incr ement by 12 as each card is added. Any cards added s ubsequently, should be placed to the left of any existing cards otherwise the channel numbering will be altered.

I/O – Analogue input/output Card (SSL ref. 904)

The Analogue Card provides 24 circuits of electronically balanced input and output. These circuits are accessed via Canon DL 96 way female connectors; mating connectors are available to order

Refer to Appendix C for the connector pinouts.

As is the case for the MicAmp, cards added subsequently should be placed to the left of existing cards.

The default line-up level for analogue I/O is 0dBFS = +18dBu. This level may be globally altered and can range from +9dBu to +24dBu. The value can be adjusted from a setup screen to match the standard operating level for the facility.

Note. When assigning analogue card output channels as insert sends, the routing system will automatically assign the same input channel number as the corresponding return. It is therefore necessary to physically wire outboard equipment so that circuit allocation follows this arrangement.

Page 33

Image 37
Contents Installation Guide Page Solid State Logic Solid State Logic Contents Introduction Electrical Safety Warning Safety ConsiderationsInstallation Instructions Voltage Selection and FusingMains Supply and Phases Safety Earth ConnectionPhysical Safety Mains Isolation and Over-Current ProtectionFCC Certification CE CertificationServices provided by SSL Pre Installation InformationWarranty CommissioningConsole Control Surface Physical RequirementsRack Mounting Equipment Centuri, NetBridge and Stageboxes Acoustic IsolationChannel Footprint Side Profile Showing Service AccessAir Conditioning Requirements Service AccessCable Ducting SB Crate side view Showing Card Access Centuri Processor Crate side view Showing Card AccessTechnical Requirements Power Connections Mains Input Voltage & CurrentVideo Sync Source GroundingEVS C100 Channel Bay LayoutC100 Console System ComponentsCenturi Processor Crate Rear View Centuri Processor Crate Front ViewCenturi Processor Console Routing/Link Card Interface System DiskCenturi Disk Card Centuri DSP CardCenturi CPU Card Centuri Console Interface Card+5V Mic Input Analogue I/O Digital I/OCenturi Analogue I/O Card Centuri Micamp CardCenturi Digital I/O Card Centuri Madi Card Copper versionMorse Router Morse 3U Stagebox SB Stagebox Front ViewMorse System option SB Stagebox optionNetBridge Rear View NetBridge Front ViewNetBridge PSU Voltage Selection NetBridge option Location Of Bellypanel USB Connectors Script Tray option External Keyboard / Trackball optionsLoudspeaker Shelf option TFT External Input optionCenturi Mains Inlet Panel Console Mains Inlet PanelNetBridge Rear Panel Power Supply Connections Installation WiringAudio Console Connector Panel Control Surface Wiring Block DiagramCPU Card Control Card Centuri to Console Surface Connections CPU Card PSU Status Wiring DiagramSync Source PSU StatusAnalogue I/O Card Micamp Input CardAnalogue input/output Card SSL ref MicAmp Card SSL refMadi I/O Card Copper version Digital I/O Card D25 versionDigital Input/Output Card 75Ω SSL ref XJ Digital Input/Output Card 110Ω SSL ref XFGPI I/O Card GPI Output circuit GPI I/O SSL ref XAGPI Input circuit SB Cabling Diagrams Fibre Link Connectors and PanelsCenturi Link Card SB CPU CardStageboxes & Fibre Links TCP/IP NetBridge InstallationAccess NetBridge InstallationRemote Diagnostics ConnectionC100 Console Talkback system Block DiagramCenturi Chassis Talkback Connections Talkback and OscillatorOscillator Connections Meter and Phasescope wiring RTW Meter and Phasescope wiring MSD 600CCenturi Crate Meters and Phasescope Gold is 1.9 times heavier than Lead Appendix a Specifications Centuri Processor Crate Net Bridge SB Micamp Rack DL 96-Pin Hood Varicon 56-pin Appendix B Connector DetailsPlugSocket Hood Free SocketDIN 5-Pin XLR 3-PinType Multipin 25-wayMeter Inputs Analogue Appendix C Connector Pinouts C100 ConsoleMSD Diag Diagnostics / Remote Control Phase Scope DigitalMachine Control Connector Pinouts Centuri ProcessorTimecode ExpansionTtya TTYD, Ttyf Ttyh RS422 SerialTtye RS232 Mic in 1 Mic Input Card ‘908Analogue in / Analogue OUT Analogue I/O Card ‘904AES/EBU In 1-8 9-16, 17-24 Digital I/O Card ‘902AES/EBU Out 1-8 9-16, 17-24 BNC Breakout PanelGPI Outputs 1 12 13 24, 25 36, 37 48, 49 GPI I/O Card ‘907NetBridge Diagnostic Cable Connector Pinouts NetBridgeSerial 1-8 RS232 TerminalC100 Installation Guide Appendix D Audio Interfacing Connecting to Unbalanced EquipmentBalanced Circuits C100 Installation Guide Appendix E Environmental Specification +4dBu = 1.229V rms dBu = 0.775V rms. -6dBu = 0.388V rms Design Requirements for a Flightcase Appendix F Additional Information for Installing StageboxesThis page is blank intentionally Cables and Accessories by Part Description Appendix G Cables and accessoriesMiscellaneous/Hardware Description SSL Part No Video & SyncAppendix G Part Numbers More Notes