Appendix C – Connector Pinouts
Appendix C: Connector Pinouts – C100 Console
| 'Meter Inputs' (Analogue) | 
 | 
 | 
 | ||||
| Location: | 
 | 
 | 'Audio' interface Panel | 
 | |||
| Connector Type: | 
 | Notes VU/PPM only | Notes RTW 10830 | ||||
| Pin | 
 | Description | + | ||||
| 1 | 14 | Meter 1 Input | Left Meter input | Analogue input 1 | |||
| 2 | Meter 1 Input | - | 
 | and Meter Left | |||
| 15 | n/c | 
 | + | Unused | Analogue input 2 | ||
| 3 | Meter 2 Input | ||||||
| 16 | Meter 2 Input | - | 
 | and Meter Right | |||
| 4 | n/c | 
 | + | Right Meter input | Analogue input 3 | ||
| 17 | Meter 3 Input | ||||||
| 5 | Meter 3 Input | - | 
 | 
 | |||
| 18 | n/c | 
 | + | Unused | Analogue input 4 | ||
| 6 | Meter 4 Input | ||||||
| 19 | Meter 4 Input | - | 
 | 
 | |||
| 7 | n/c | 
 | + | Unused | Analogue input 5 | ||
| 20 | Meter 5 Input | ||||||
| 8 | Meter 5 Input | - | 
 | 
 | |||
| 21 | n/c | 
 | + | Unused | Analogue input 6 | ||
| 9 | Meter 6 Input | ||||||
| 22 | Meter 6 Input | - | 
 | 
 | |||
| 10 | n/c | 
 | + | Unused | Analogue input 7 | ||
| 23 | Meter 7 Input | ||||||
| 11 | Meter 7 Input | - | 
 | 
 | |||
| 24 | n/c | 
 | + | Unused | Analogue input 8 | ||
| 12 | Meter 8 Input | ||||||
| 25 | Meter 8 Input | - | 
 | 
 | |||
| 13 | n/c | 
 | 
 | 
 | 
 | ||
| 
 | n/c | 
 | 
 | 
 | 
 | ||
Note. If both the RTW phasescope and mechanical meters are fitted refer to the RTW circuit allocations.
Page 53