Solid State Logic 82S6PC1010C manual NetBridge Installation, Connection, Access, File Transfer

Page 45

Section 5Installation Wiring

NetBridge Installation

NetBridge has ei ght serial po rts plus two Ethernet po rts. The first Ethernet port is conn ected to the C100’s network. The s econd por t is for co nnection to t he I nternet; this can be via DHCP server (for a dy namically assigned IP address), or a static IP address defined by the operator. The IP number (in ‘dot’ not ation) will be shown on the front panel while the unit is powered.

In facilities with a firewall to the Internet, this address is likely to be for internal use within the installation and not visible to the ou tside w orld. For extern al diag nostic access, the firewall will have to be s et to pass (and redirect) t he appropr iate inco ming traffic to t he NetBr idge unit , which will have to be ag reed with and configured by the facility’s IT staff.

NetBridge operation is more fully described in a separate document which is supplied with the hardware.

Connection

The eight serial ports are all located on the single 62-pin connector (a breakout adaptor is provided). Serial ports 1 to 7 can be connected to the ‘Console’ port on the Centuri’s CPU card (on port TTY-E), allowing one NetBridge to have terminal diagnostic access to up to seven C100 processors.

Serial port 8 may be connected to a data terminal (or software terminal emulator) for permanent local diagnostic access without requiring login. (see Appendix C for cable details)

Access

For security purposes, the NetBridge file transfer functions can o nly be ac cessed by one regis tered user who must be logged into the Central File Server (CFS). This uses the secure HTTPS protocol, which must be passed through any firewall (and redirected as required), although this is unlikely to cause any security concerns as it has 128bit Secure Socket Layer encryption. For file transfer between the console and the CFS, the u ser must be logged in at the console itself. For file transfer between the CFS and another computer (eg. authorised freelance engineer or SSL support staff), the user may login from an Internet connection, with the same username and password security requirements.

Diagnostic acce ss a lso us es ‘Sec ure So cket L ayer’ enc rypted lo gin, and is availab le to multiple us ers simultaneously over the TCP/IP network link. They can log-in as terminal users and each run the terminal client application on the NetBridge to give them switched access to the seven serial ports.

File Transfer

If a console operator wishes to export a session template to the CFS so that others may create offline setups from it, secure login from the C100 allows that file to be uploaded to the facility’s private account on the CFS, so that registered users can download the t emplate and upload t heir own setup s. Any existing setups in th at account can be downloaded from the CFS to the console’s hard disk.

Remote Diagnostics

In order to access a C100’s diagnostics through its NetBridge, first you need to know the IP address of that unit (on the front panel, or defined by a firewall/router), which can be determined by contacting the facility’s IT staff or consulting the security arrangements agreed with them. Once a secure connection has been made, running the terminal server application on the NetBridge will allow y ou to connect from the Internet to any of the seven ‘console diagnostic’ ports on that NetBridge.

Page 41

Image 45
Contents Installation Guide Page Solid State Logic Solid State Logic Contents Introduction Electrical Safety Warning Safety ConsiderationsInstallation Instructions Voltage Selection and FusingMains Supply and Phases Safety Earth ConnectionPhysical Safety Mains Isolation and Over-Current ProtectionFCC Certification CE CertificationServices provided by SSL Pre Installation InformationWarranty CommissioningConsole Control Surface Physical RequirementsRack Mounting Equipment Centuri, NetBridge and Stageboxes Acoustic IsolationChannel Footprint Side Profile Showing Service AccessService Access Air Conditioning RequirementsCable Ducting SB Crate side view Showing Card Access Centuri Processor Crate side view Showing Card AccessTechnical Requirements Power Connections Mains Input Voltage & CurrentVideo Sync Source GroundingEVS C100 Channel Bay LayoutC100 Console System ComponentsCenturi Processor Crate Rear View Centuri Processor Crate Front ViewCenturi Processor Console Routing/Link Card Interface System DiskCenturi Disk Card Centuri DSP CardCenturi CPU Card Centuri Console Interface Card+5V Mic Input Analogue I/O Digital I/OCenturi Analogue I/O Card Centuri Micamp CardCenturi Digital I/O Card Centuri Madi Card Copper versionMorse Router Morse 3U Stagebox SB Stagebox Front ViewMorse System option SB Stagebox optionNetBridge Front View NetBridge Rear ViewNetBridge PSU Voltage Selection NetBridge option Location Of Bellypanel USB Connectors Script Tray option External Keyboard / Trackball optionsLoudspeaker Shelf option TFT External Input optionConsole Mains Inlet Panel Centuri Mains Inlet PanelNetBridge Rear Panel Power Supply Connections Installation WiringControl Surface Wiring Block Diagram Audio Console Connector PanelCPU Card Control Card Centuri to Console Surface Connections CPU Card PSU Status Wiring DiagramSync Source PSU StatusAnalogue I/O Card Micamp Input CardAnalogue input/output Card SSL ref MicAmp Card SSL refMadi I/O Card Copper version Digital I/O Card D25 versionDigital Input/Output Card 75Ω SSL ref XJ Digital Input/Output Card 110Ω SSL ref XFGPI I/O Card GPI I/O SSL ref XA GPI Output circuitGPI Input circuit SB Cabling Diagrams Fibre Link Connectors and PanelsCenturi Link Card SB CPU CardStageboxes & Fibre Links TCP/IP NetBridge InstallationAccess NetBridge InstallationRemote Diagnostics ConnectionTalkback system Block Diagram C100 ConsoleCenturi Chassis Talkback and Oscillator Talkback ConnectionsOscillator Connections Meter and Phasescope wiring MSD 600C Meter and Phasescope wiring RTWCenturi Crate Meters and Phasescope Gold is 1.9 times heavier than Lead Appendix a Specifications Centuri Processor Crate Net Bridge SB Micamp Rack DL 96-Pin Hood Varicon 56-pin Appendix B Connector DetailsPlugSocket Hood Free SocketDIN 5-Pin XLR 3-PinType Multipin 25-wayMeter Inputs Analogue Appendix C Connector Pinouts C100 ConsoleMSD Diag Diagnostics / Remote Control Phase Scope DigitalMachine Control Connector Pinouts Centuri ProcessorTimecode ExpansionSerial Ttya TTYD, Ttyf Ttyh RS422Ttye RS232 Mic in 1 Mic Input Card ‘908Analogue in / Analogue OUT Analogue I/O Card ‘904AES/EBU In 1-8 9-16, 17-24 Digital I/O Card ‘902AES/EBU Out 1-8 9-16, 17-24 BNC Breakout PanelGPI Outputs 1 12 13 24, 25 36, 37 48, 49 GPI I/O Card ‘907NetBridge Diagnostic Cable Connector Pinouts NetBridgeSerial 1-8 RS232 TerminalC100 Installation Guide Connecting to Unbalanced Equipment Appendix D Audio InterfacingBalanced Circuits C100 Installation Guide Appendix E Environmental Specification +4dBu = 1.229V rms dBu = 0.775V rms. -6dBu = 0.388V rms Design Requirements for a Flightcase Appendix F Additional Information for Installing StageboxesThis page is blank intentionally Cables and Accessories by Part Description Appendix G Cables and accessoriesMiscellaneous/Hardware Description SSL Part No Video & SyncAppendix G Part Numbers More Notes