Solid State Logic 82S6PC1010C manual GPI I/O SSL ref XA, GPI Output circuit, GPI Input circuit

Page 41

Section 5

 

Installation Wiring

 

 

 

 

I/O – GPI I/O (SSL ref. 907XA)

The GPI I/O Card contains 60 circuits of opto-isolated input and 60 circuits of relay-closure output. Inputs are accessed by 25-pin D-type male connectors and outputs by 25-pin D-type female connectors; mating connector kits are available to order.

Both the input and the output circuits are fully isolated from th e processor electronics. On output connectors, there is a protected source of +15V available an, a 0V reference is available on input connectors.

The input and output signals can be either latching or momentary; this is individually assigned in software using the touch screen. When set to momentary, the input signal duration needs to be greater than 50mS.

Note: When used for track arming and tally, the tally must return to the same number input as the output signal.(ie. the tally for GPI out 1 will be on GPI in 1).

The switch closure is by DIL relay. Contact rating is 100Vdc, 125Vac, 100mA max. Do not use the output contacts to directly switch capacitive or reactive loads; always use an external relay with a suitable contact rating.

Contact A

GPI Output circuit

Contact B

The signal input requires AC or DC voltage between 4V and 30V. The current drawn is approximately 10mA.

GPI in

Input A

GPI Input circuit

Input B

Page 37

Image 41
Contents Installation Guide Page Solid State Logic Solid State Logic Contents Introduction Electrical Safety Warning Safety ConsiderationsInstallation Instructions Voltage Selection and FusingMains Supply and Phases Safety Earth ConnectionPhysical Safety Mains Isolation and Over-Current ProtectionFCC Certification CE CertificationServices provided by SSL Pre Installation InformationWarranty CommissioningConsole Control Surface Physical RequirementsRack Mounting Equipment Centuri, NetBridge and Stageboxes Acoustic IsolationChannel Footprint Side Profile Showing Service AccessCable Ducting Service AccessAir Conditioning Requirements SB Crate side view Showing Card Access Centuri Processor Crate side view Showing Card AccessTechnical Requirements Power Connections Mains Input Voltage & CurrentVideo Sync Source GroundingEVS C100 Channel Bay LayoutC100 Console System ComponentsCenturi Processor Crate Rear View Centuri Processor Crate Front ViewCenturi Processor Console Routing/Link Card Interface System DiskCenturi Disk Card Centuri DSP CardCenturi CPU Card Centuri Console Interface Card+5V Mic Input Analogue I/O Digital I/OCenturi Analogue I/O Card Centuri Micamp CardCenturi Digital I/O Card Centuri Madi Card Copper versionMorse Router Morse 3U Stagebox SB Stagebox Front ViewMorse System option SB Stagebox optionNetBridge PSU Voltage Selection NetBridge Front ViewNetBridge Rear View NetBridge option Location Of Bellypanel USB Connectors Script Tray option External Keyboard / Trackball optionsLoudspeaker Shelf option TFT External Input optionNetBridge Rear Panel Console Mains Inlet PanelCenturi Mains Inlet Panel Power Supply Connections Installation WiringCPU Card Control Card Control Surface Wiring Block DiagramAudio Console Connector Panel Centuri to Console Surface Connections CPU Card PSU Status Wiring DiagramSync Source PSU StatusAnalogue I/O Card Micamp Input CardAnalogue input/output Card SSL ref MicAmp Card SSL ref Madi I/O Card Copper version Digital I/O Card D25 versionDigital Input/Output Card 75Ω SSL ref XJ Digital Input/Output Card 110Ω SSL ref XFGPI I/O Card GPI Input circuit GPI I/O SSL ref XAGPI Output circuit SB Cabling Diagrams Fibre Link Connectors and PanelsCenturi Link Card SB CPU CardStageboxes & Fibre Links TCP/IP NetBridge InstallationAccess NetBridge InstallationRemote Diagnostics ConnectionCenturi Chassis Talkback system Block DiagramC100 Console Oscillator Connections Talkback and OscillatorTalkback Connections Centuri Crate Meter and Phasescope wiring MSD 600CMeter and Phasescope wiring RTW Meters and Phasescope Gold is 1.9 times heavier than Lead Appendix a Specifications Centuri Processor Crate Net Bridge SB Micamp Rack DL 96-Pin Hood Varicon 56-pin Appendix B Connector DetailsPlugSocket Hood Free SocketDIN 5-Pin XLR 3-PinType Multipin 25-wayMeter Inputs Analogue Appendix C Connector Pinouts C100 ConsoleMSD Diag Diagnostics / Remote Control Phase Scope DigitalMachine Control Connector Pinouts Centuri ProcessorTimecode ExpansionTtye RS232 SerialTtya TTYD, Ttyf Ttyh RS422 Mic in 1 Mic Input Card ‘908Analogue in / Analogue OUT Analogue I/O Card ‘904AES/EBU In 1-8 9-16, 17-24 Digital I/O Card ‘902AES/EBU Out 1-8 9-16, 17-24 BNC Breakout PanelGPI Outputs 1 12 13 24, 25 36, 37 48, 49 GPI I/O Card ‘907NetBridge Diagnostic Cable Connector Pinouts NetBridgeSerial 1-8 RS232 TerminalC100 Installation Guide Balanced Circuits Connecting to Unbalanced EquipmentAppendix D Audio Interfacing C100 Installation Guide Appendix E Environmental Specification +4dBu = 1.229V rms dBu = 0.775V rms. -6dBu = 0.388V rms Design Requirements for a Flightcase Appendix F Additional Information for Installing StageboxesThis page is blank intentionally Cables and Accessories by Part Description Appendix G Cables and accessoriesMiscellaneous/Hardware Description SSL Part No Video & SyncAppendix G Part Numbers More Notes