System Components

 

Section 4 – System Components

This sec tion gives an overview of the main un its in t he system. See A ppendix A for specifications and Appendices B and C for connector details and pinouts.

C100 Console

Each console control surface will consist of one Centre Section and can be specified to have from 8 to 96 channel faders in groups of 8. (Note: a group of 8 faders and controls and its frame is termed a bay). See page 10 for frame sizes.

Each console channel-bay consists of four sections: Faders, Channel Control, Master Channel and the meters. It is only necessary to have one Master Channel tile fitted t o the c onsole frame as this c an be used to access all channels, although for convenience and additio nal flexibility additional Channel Mas ters may be fitte d to any bay.

Only the faders are removable individually, all other panels (termed tiles) are 8 channels wide.

Note that the number of physical faders fitted does not limit the number of processing channels available; this is determined by the amount of DSP resource fitted to the processor.

The Centre Section may optionally be specified with a 6 or 8-channel LCD phase-scope and has additional space for mechanical meters. Alternatively, a range of custom meter configurations is possible; these should be detailed at the time of order.

The console frame may be specified to have 19” wide sections for script space (known as ‘Pro ducer’s’ tables). These can be fitted with either a full-depth flat table or a shorter table and 7U of equipment racking. A 7.2° corner section is also available to create angled frames.

Every C 100 co nsole is fitted with dual redundant power supplies as s tandard. Acc ordingly, there are two separate mains input connectors beneath the console.

The standard moulded end trims can be substituted by a thin trim panel (approximately 8mm) for installations where width is limited.

SSL's Project Engineering Department can provide specific console footprint drawings detailing layout, size and metering options during the specification process.

Page 13

Image 17
Contents Installation Guide Page Solid State Logic Solid State Logic Contents Introduction Electrical Safety Warning Safety ConsiderationsInstallation Instructions Voltage Selection and FusingMains Supply and Phases Safety Earth ConnectionPhysical Safety Mains Isolation and Over-Current ProtectionFCC Certification CE CertificationServices provided by SSL Pre Installation InformationWarranty CommissioningConsole Control Surface Physical RequirementsRack Mounting Equipment Centuri, NetBridge and Stageboxes Acoustic IsolationChannel Footprint Side Profile Showing Service AccessCable Ducting Service AccessAir Conditioning Requirements SB Crate side view Showing Card Access Centuri Processor Crate side view Showing Card AccessTechnical Requirements Power Connections Mains Input Voltage & CurrentVideo Sync Source GroundingEVS C100 Channel Bay LayoutC100 Console System ComponentsCenturi Processor Crate Rear View Centuri Processor Crate Front ViewCenturi Processor Console Routing/Link Card Interface System DiskCenturi Disk Card Centuri DSP CardCenturi CPU Card Centuri Console Interface Card+5V Mic Input Analogue I/O Digital I/OCenturi Analogue I/O Card Centuri Micamp CardCenturi Digital I/O Card Centuri Madi Card Copper versionMorse Router Morse 3U Stagebox SB Stagebox Front ViewMorse System option SB Stagebox optionNetBridge PSU Voltage Selection NetBridge Front ViewNetBridge Rear View NetBridge option Location Of Bellypanel USB Connectors Script Tray option External Keyboard / Trackball optionsLoudspeaker Shelf option TFT External Input optionNetBridge Rear Panel Console Mains Inlet PanelCenturi Mains Inlet Panel Power Supply Connections Installation WiringCPU Card Control Card Control Surface Wiring Block DiagramAudio Console Connector Panel Centuri to Console Surface Connections CPU Card PSU Status Wiring DiagramSync Source PSU StatusAnalogue I/O Card Micamp Input CardAnalogue input/output Card SSL ref MicAmp Card SSL refMadi I/O Card Copper version Digital I/O Card D25 versionDigital Input/Output Card 75Ω SSL ref XJ Digital Input/Output Card 110Ω SSL ref XFGPI I/O Card GPI Input circuit GPI I/O SSL ref XAGPI Output circuit SB Cabling Diagrams Fibre Link Connectors and PanelsCenturi Link Card SB CPU CardStageboxes & Fibre Links TCP/IP NetBridge InstallationAccess NetBridge InstallationRemote Diagnostics ConnectionCenturi Chassis Talkback system Block DiagramC100 Console Oscillator Connections Talkback and OscillatorTalkback Connections Centuri Crate Meter and Phasescope wiring MSD 600CMeter and Phasescope wiring RTW Meters and Phasescope Gold is 1.9 times heavier than Lead Appendix a Specifications Centuri Processor Crate Net Bridge SB Micamp Rack DL 96-Pin Hood Varicon 56-pin Appendix B Connector DetailsPlugSocket Hood Free SocketDIN 5-Pin XLR 3-PinType Multipin 25-wayMeter Inputs Analogue Appendix C Connector Pinouts C100 ConsoleMSD Diag Diagnostics / Remote Control Phase Scope DigitalMachine Control Connector Pinouts Centuri ProcessorTimecode ExpansionTtye RS232 SerialTtya TTYD, Ttyf Ttyh RS422 Mic in 1 Mic Input Card ‘908Analogue in / Analogue OUT Analogue I/O Card ‘904AES/EBU In 1-8 9-16, 17-24 Digital I/O Card ‘902AES/EBU Out 1-8 9-16, 17-24 BNC Breakout PanelGPI Outputs 1 12 13 24, 25 36, 37 48, 49 GPI I/O Card ‘907NetBridge Diagnostic Cable Connector Pinouts NetBridgeSerial 1-8 RS232 TerminalC100 Installation Guide Balanced Circuits Connecting to Unbalanced EquipmentAppendix D Audio Interfacing C100 Installation Guide Appendix E Environmental Specification +4dBu = 1.229V rms dBu = 0.775V rms. -6dBu = 0.388V rms Design Requirements for a Flightcase Appendix F Additional Information for Installing StageboxesThis page is blank intentionally Cables and Accessories by Part Description Appendix G Cables and accessoriesMiscellaneous/Hardware Description SSL Part No Video & SyncAppendix G Part Numbers More Notes