Sony SRP-X500P manual Master Volume UP 0x43 0x4C 0x56 0x2B ‘CLV+’, Master Volume Level 1st byte

Page 12

SRP-X500P RS-232C Interface Manual

Parameter

The parameter consists of 7 bytes of data in the order shown in the following table.

Byte

Parameter

1st

MASTER VOLUME LEVEL

2nd

REMOTE 1 LEVEL

3rd

REMOTE 2 LEVEL

4th

REMOTE 3 LEVEL

5th

REMOTE 4 LEVEL

6th

REMOTE 5 LEVEL

7th

REMOTE 6 LEVEL

MASTER VOLUME LEVEL (1st byte)

The master volume level is shown (in dB units).

The correspondence of the parameter with the level setting is the same as that of the FADER parameter of the INPUT FADER command (page 7).

REMOTE 1-6 LEVEL (2nd-7th byte)

The level of each REMOTE fader is shown (in dB units).

The correspondence of the parameter with the level setting is the same as that of the LEVEL parameter of the REMOTE 1-6 LEVEL command (page 10).

2.1.9 MASTER VOLUME UP : 0x43 0x4C 0x56 0x2B (‘CLV+’)

This command is used to turn up the master volume.

When this command is transmitted, the volume increases continuously. When the MASTER VOLUME STOP command (page 13) is transmitted, the volume level stops increasing.

To read the control status of the MASTER VOLUME motor from the SRP-X500P, use the STATUS REQUEST command (page 23).

To read the master volume level setting from the SRP-X500P, use the REMOTE FADER LEVEL PARAMETER REQUEST command (page 11).

Packet format

0x43 0x4C 0x56 0x2B parameter” 0x0D

Parameter

The parameter consists of 1 byte of data.

Be sure to use 0x40(‘@’) for this parameter.

Example

To turn up the master volume level: 0x43 0x4C 0x56 0x2B 0x40 0x0D (‘C L V + @ CR’)

Page 12/43

Image 12
Contents SRP-X500P Table of Contents Connecting the SRP-X500P to a Computer About This Manual3 4 RS-232C indicator Communication FormatCommunication Protocol Handshake Codes Communication Packet FormatBasic Control Commands 1 AV/RGB Input Select 0x43 0x53 0x45 0x4C ‘CSEL’Input Fader 0x43 0x50 0x4D 0x35 ‘CPM5’ Return packet formatInput Fader Request 0x52 0x50 0x4D 0x35 ‘RPM5’ Fader 1st-6th byte Output Fader 0x43 0x50 0x4D 0x40 ‘CPM@’ Output Fader Request 0x52 0x50 0x4D 0x40 ‘RPM@’ Fader 1st-8th byte Remote 1-6 Level 0x43 0x4C 0x56 0x4C ‘CLVL’ Channel 1st byteRemote Level 2nd byte Master Volume UP 0x43 0x4C 0x56 0x2B ‘CLV+’ Master Volume Level 1st byteRemote 1-6 Level 2nd-7th byte Master Volume Down 0x43 0x4C 0x56 0x2D ‘CLV-’ Master Volume Stop 0x43 0x4C 0x56 0x53 ‘CLVS’Muting 0x43 0x4D 0x55 0x54 ‘CMUT’ Muting 2nd byteMuting Parameter Request 0x52 0x4D 0x55 0x54 ‘RMUT’ Input Muting 1st byteSpeaker Output Muting 2nd byte Line Output Muting 3rd byte Master Muting 4th byteRemote Muting 5th byte MasterProjector ON/STANDBY 0x43 0x50 0x4A 0x50 ‘CPJP’ Projector Control Request 1st byteProjector ON/STANDBY Indicator 1st byte Scene Recall 0x43 0x52 0x43 0x4C ‘CRCL’Scene Recall Request 1st byte Scene Recall RequestScene Recall Parameter Request 0x52 0x52 0x43 0x4C ‘RRCL’ Scene No st byteStatus Acquisition Commands Index Request 0x52 0x50 0x4D 0x44 ‘RPMD’Index Level Meter Parameter Request 0x52 0x4D 0x54 0x52 ‘RMTR’ Level Meter 1st-16th byte To acquire status of single item To acquire the status of all items Parameters Input Volume 3rd-8th byte Master Volume Level 9th byteRemote 1-6 Level 10th-15th byte Input Level 16th-21st byte Output Level 22nd-29th byteInput Muting 30th byte Output Muting 31st and 32nd byte Speaker Output MutingLine Output Muting Master Muting 33rd byteRF/AF Indicator 36th byte WL Indicator 37th byte+48V Switch 38th byte MIC 1-4 Trim 39th-42nd byteREF Indicator 49th byte Line Trim 43rd byteAV/RGB Trim 44th-48th byte FR Setup Status 54th and 55th byte Setup ChannelFR 50th-53rd byte Setup Status AV/RGB Input Select 56th byteSpeaker Output Level 57th, 58th byte Speaker Output CH1/2 LevelIR Output Mode Indicator 59th byte Clip Indicator 77th byteLevel Meter 60th-75th byte Protection 76th byteTemperature 78th and 79th byte TemperatureProjector ON/STANDBY Indicator 80th byte EMG Muting 83rd byteScene No th byte Parallel Input 85th-94th byteLevel Parallel Output 95th and 96th byteMaster Volume Control 98th byte OutputFAN Motor 97th byte OUT6 OUT5 OUT4 OUT3 OUT2Gain Reduction 99th-108th byte AGC Gain ControlCompressor Gain Reduction Maintenance Information Commands Information SETUPDATE2005/01/23Information Request 0x52 0x50 0x4D 0x45 ‘RPME’ InformationMaintenance Information Read Write Maintenance Information Read WriteMaintenance Information Read only Maintenance Information Read onlyVersion Request 0x52 0x56 0x45 0x52 ‘RVER’ VersionVersion Factory Preset 0x43 0x52 0x53 0x54 ‘CRST’
Related manuals
Manual 6 pages 29.24 Kb