Parameters
The parameter consists of 108 bytes of data, as shown in the following table.
Byte (when | Parameter | Specified value | Parameter byte(s) | |
acquiring all |
| (when acquiring | (when acquiring | |
items at one time) |
| single item) | single item) | |
1st | PROJECTOR PROTOCOL SWITCH | 0x51 | (‘Q’) | 1 |
2nd | SYSTEM TYPE SWITCH | 0x52 | (‘R’) | 1 |
INPUT VOLUME | 0x53 | (‘S’) | 6 | |
9th | MASTER VOLUME LEVEL | 0x54 | (‘T’) | 1 |
10th | REMOTE 1 LEVEL | 0x55 | (‘U’) | 1 |
11th | REMOTE 2 LEVEL | 0x56 | (‘V’) | 1 |
12th | REMOTE 3 LEVEL | 0x57 | (‘W’) | 1 |
13th | REMOTE 4 LEVEL | 0x58 | (‘X’) | 1 |
14th | REMOTE 5 LEVEL | 0x59 | (‘Y’) | 1 |
15th | REMOTE 6 LEVEL | 0x5A (‘Z’) | 1 | |
INPUT LEVEL | 0x5B (‘[‘] | 6 | ||
OUTPUT LEVEL | 0x5C (‘\’) | 8 | ||
30th | INPUT MUTING | 0x5D (‘]’) | 1 | |
31st, 32nd | OUTPUT MUTING | 0x5E (‘^’) | 2 | |
33rd | MASTER MUTING | 0x5F (‘_’) | 1 | |
34th | REMOTE MUTING | 0x60 | (‘`’) | 1 |
35th | (RESERVED) |
|
|
|
36th | RF/AF INDICATOR | 0x61 | (‘a’) | 1 |
37th | WL INDICATOR | 0x62 | (‘b’) | 1 |
38th | +48V SWITCH | 0x63 | (‘c’) | 1 |
39th | MIC 1 TRIM | 0x64 | (‘d’) | 1 |
40th | MIC 2 TRIM | 0x65 | (‘e’) | 1 |
41st | MIC 3 TRIM | 0x66 | (‘f’) | 1 |
42nd | MIC 4 TRIM | 0x67 | (‘g’) | 1 |
43rd | LINE TRIM | 0x68 | (‘h’) | 1 |
AV/RGB TRIM | 0x69 | (‘i’) | 5 | |
49th | REF INDICATOR | 0x6A (‘j’) | 1 | |
FR | 0x6B (‘k’) | 4 | ||
54th,55th | FR SETUP STATUS | 0x6C (‘l’) | 2 | |
56th | AV/RGB INPUT SELECT | 0x6D (‘m’) | 1 | |
57th, 58th | SPEAKER OUTPUT LEVEL | 0x6E (‘n’) | 2 | |
59th | IR OUTPUT MODE INDICATOR | 0x6F (‘o’) | 1 | |
LEVEL METER | 0x70 | (‘p’) | 16 | |
76th | PROTECTION | 0x71 | (‘q’) | 1 |
77th | CLIP INDICATOR | 0x72 | (‘r’) | 1 |
78th, 79th | TEMPERATURE | 0x73 | (‘s’) | 2 |
80th | PROJECTOR ON/STANDBY | 0x74 | (‘t’) | 1 |
| INDICATOR |
|
|
|
81st, 82nd | (RESERVED) |
|
|
|
83rd | EMG MUTING | 0x77 | (‘w’) | 1 |
84th | SCENE No. | 0x78 | (‘x’) | 1 |
PARALLEL INPUT | 0x79 | (‘y’) | 10 | |
95th, 96th | PARALLEL OUTPUT | 0x7A (‘z’) | 2 | |
97th | FAN MOTOR | 0x7B (‘{‘} | 1 | |
98th | MASTER VOLUME CONTROL | 0x7C (‘’) | 1 | |
GAIN REDUCTION | 0x7D (‘}’) | 10 |
The parameters returned have the following meanings.
Page 25/43