LEVEL (2nd byte)

The level for each fader can be specified (in dB units).

The parameter and the level are as shown in the following table.

Level

-

0x30 (‘0’)

-70.0

0x31 (‘1’)

-60.0

0x32 (‘2’)

-55.0

0x33 (‘3’)

-50.0

0x34 (‘4’)

-45.0

0x35 (‘5’)

-40.0

0x36 (‘6’)

-35.0

0x37 (‘7’)

-32.5

0x38 (‘8’)

-30.0

0x39 (‘9’)

-27.5

0x3A (‘:’)

-25.0

0x3B (‘;’)

-24.0

0x3C (‘<‘)

-23.0

0x3D (‘=‘)

-22.0

0x3E (‘>‘)

-21.0

0x3F (‘?’)

Level

-20.0

0x40

(‘@’)

-19.0

0x41

(‘A’)

-18.0

0x42

(‘B’)

-17.0

0x43

(‘C’)

-16.0

0x44

(‘D’)

-15.0

0x45

(‘E’)

-14.0

0x46

(‘F’)

-13.0

0x47

(‘G’)

-12.0

0x48

(‘H’)

-11.0

0x49

(‘I’)

-10.0

0x4A (‘J’)

-9.0

0x4B (‘K’)

-8.0

0x4C (‘L’)

-7.0

0x4D (‘M’)

-6.0

0x4E (‘N’)

-5.0

0x4F (‘O’)

Level

 

 

-4.5

0x50

(‘P’)

-4.0

0x51

(‘Q’)

-3.5

0x52

(‘R’)

-3.0

0x53

(‘S’)

-2.5

0x54

(‘T’)

-2.0

0x55

(‘U’)

-1.5

0x56

(‘V’)

-1.0

0x57

(‘W’)

-0.5

0x58

(‘X’)

0

0x59

(‘Y’)

Example

To set the REMOTE fader 1 to 0 dB 0x43 0x4C 0x56 0x4C 0x42 0x59 0x0D (‘C L V L B Y CR’)

2.1.8REMOTE FADER LEVEL PARAMETER REQUEST : 0x52 0x4C 0x56 0x4C (‘RLVL’)

This command is used to read the master volume and REMOTE fader level settings from the SRP-X500P.

Packet format

0x52 0x4C 0x56 0x4C 0x0D

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK (0x41 (‘A’)) in the order shown below.

0x41 parameter” 0x0D

Page 11/43

Image 11
Contents SRP-X500P Table of Contents 3 4 Connecting the SRP-X500P to a ComputerAbout This Manual Communication Protocol RS-232C indicatorCommunication Format Communication Packet Format Handshake Codes1 AV/RGB Input Select 0x43 0x53 0x45 0x4C ‘CSEL’ Basic Control CommandsReturn packet format Input Fader 0x43 0x50 0x4D 0x35 ‘CPM5’Fader 1st-6th byte Input Fader Request 0x52 0x50 0x4D 0x35 ‘RPM5’Fader 1st-8th byte Output Fader 0x43 0x50 0x4D 0x40 ‘CPM@’Output Fader Request 0x52 0x50 0x4D 0x40 ‘RPM@’ Remote Remote 1-6 Level 0x43 0x4C 0x56 0x4C ‘CLVL’Channel 1st byte Level 2nd byte Remote 1-6 Level 2nd-7th byte Master Volume UP 0x43 0x4C 0x56 0x2B ‘CLV+’Master Volume Level 1st byte Master Volume Stop 0x43 0x4C 0x56 0x53 ‘CLVS’ Master Volume Down 0x43 0x4C 0x56 0x2D ‘CLV-’Muting 2nd byte Muting 0x43 0x4D 0x55 0x54 ‘CMUT’Speaker Output Muting 2nd byte Muting Parameter Request 0x52 0x4D 0x55 0x54 ‘RMUT’Input Muting 1st byte Master Line Output Muting 3rd byteMaster Muting 4th byte Remote Muting 5th byteProjector Control Request 1st byte Projector ON/STANDBY 0x43 0x50 0x4A 0x50 ‘CPJP’Scene Recall Request Projector ON/STANDBY Indicator 1st byteScene Recall 0x43 0x52 0x43 0x4C ‘CRCL’ Scene Recall Request 1st byteScene No st byte Scene Recall Parameter Request 0x52 0x52 0x43 0x4C ‘RRCL’Index Status Acquisition CommandsIndex Request 0x52 0x50 0x4D 0x44 ‘RPMD’ Level Meter Parameter Request 0x52 0x4D 0x54 0x52 ‘RMTR’ Level Meter 1st-16th byte To acquire status of single item To acquire the status of all items Parameters Remote 1-6 Level 10th-15th byte Input Volume 3rd-8th byteMaster Volume Level 9th byte Input Muting 30th byte Input Level 16th-21st byteOutput Level 22nd-29th byte Master Muting 33rd byte Output Muting 31st and 32nd byteSpeaker Output Muting Line Output MutingMIC 1-4 Trim 39th-42nd byte RF/AF Indicator 36th byteWL Indicator 37th byte +48V Switch 38th byteAV/RGB Trim 44th-48th byte REF Indicator 49th byteLine Trim 43rd byte FR 50th-53rd byte FR Setup Status 54th and 55th byteSetup Channel Speaker Output CH1/2 Level Setup StatusAV/RGB Input Select 56th byte Speaker Output Level 57th, 58th byteProtection 76th byte IR Output Mode Indicator 59th byteClip Indicator 77th byte Level Meter 60th-75th byteEMG Muting 83rd byte Temperature 78th and 79th byteTemperature Projector ON/STANDBY Indicator 80th byteParallel Output 95th and 96th byte Scene No th byteParallel Input 85th-94th byte LevelOUT6 OUT5 OUT4 OUT3 OUT2 Master Volume Control 98th byteOutput FAN Motor 97th byteAGC Gain Control Gain Reduction 99th-108th byteCompressor Gain Reduction Information Maintenance Information CommandsInformation SETUPDATE2005/01/23 Information Request 0x52 0x50 0x4D 0x45 ‘RPME’Maintenance Information Read Write Maintenance Information Read WriteMaintenance Information Read only Maintenance Information Read onlyVersion Version Request 0x52 0x56 0x45 0x52 ‘RVER’Version Factory Preset 0x43 0x52 0x53 0x54 ‘CRST’