Sony SRP-X500P manual Level Meter Parameter Request 0x52 0x4D 0x54 0x52 ‘RMTR’, MIC 1/WL 1 Input

Page 21

SRP-X500P RS-232C Interface Manual

Example

When the input/output channels are specified with the index names as follows:

MIC 1/WL 1 INPUT

: MIC1

MIC 2/WL 2 INPUT

: MIC2

MIC 3 INPUT

: MIC3

MIC 4 INPUT

: MIC4

LINE INPUT

: MD

AV/RGB INPUT A

: CD

AV/RGB INPUT B

: DVD

AV/RGB INPUT C

: CASSETTE

AV/RGB INPUT D

: PC1

AV/RGB INPUT E

: PC2

SPEAKER OUTPUT 1

: SP1

SPEAKER OUTPUT 2

: SP2

SPEAKER OUTPUT 3

: SP3

SPEAKER OUTPUT 4

: SP4

LINE OUTPUT 1

: AUXL

LINE OUTPUT 2

: AUXR

LINE OUTPUT 3

: RECL

LINE OUTPUT 4

: RECR

0x41 0x4D 0x49 0x43 0x20 0x31 0x20 0x20 0x20 0x4D 0x49 0x43 0x20 0x32 0x20 0x20 0x20 0x4D 0x49 0x43 0x20 0x33 0x20 0x20 0x20 0x4D 0x49 0x43 0x20 0x34 0x20 0x20 0x20 0x4D 0x44 0x20 0x20 0x20 0x20 0x20 0x20 0x43 0x44 0x20 0x20 0x20 0x20 0x20 0x20 0x44 0x56 0x44 0x20 0x20 0x20 0x20 0x20 0x43 0x41 0x53 0x53 0x45 0x54 0x54 0x45 0x50 0x43 0x20 0x31 0x20 0x20 0x20 0x20 0x50 0x43 0x20 0x32 0x20 0x20 0x20 0x20 0x53 0x43 0x20 0x31 0x20 0x20 0x20 0x20 0x53 0x43 0x20 0x32 0x20 0x20 0x20 0x20 0x53 0x43 0x20 0x33 0x20 0x20 0x20 0x20 0x53 0x43 0x20 0x34 0x20 0x20 0x20 0x20 0x41 0x55 0x58 0x20 0x4C 0x20 0x20 0x20 0x41 0x55 0x58 0x20 0x52 0x20 0x20 0x20 0x52 0x45 0x43 0x20 0x4C 0x20 0x20 0x20 0x52 0x45 0x43 0x20 0x52 0x20 0x20 0x20 0x0D

(‘A M I C 1 □ □ □ M I C 2 □ □ □ M I C 3 □ □ □ M I C 4 □ □ □ M D □ □ □ □ □

C D □ □ □ □ □ □ D V D □ □ □ □ □ C A S S E T T E P C 1 □ □ □ □ P C 2 □ □ □

S P 3 □ □ □ □ S P 4 □ □ □ □ A U X L □ □ □ A U X R □ □ □ R E C L □ □

R E C R □ □ □ CR’) “” indicates a space.

2.2.2LEVEL METER PARAMETER REQUEST : 0x52 0x4D 0x54 0x52 (‘RMTR’)

This command is used to read the level meter indication from the SRP-X500P.

The parameter shown for this command indicates the level meter reading in the BLOCK screen and the OVER VIEW screen of the SRP-X500P Manager.

Packet format

0x52 0x4D 0x54 0x52 0x0D

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK (0x41 (‘A’)) in the order shown below.

0x41 parameter” 0x0D

Page 21/43

Image 21
Contents SRP-X500P Table of Contents Connecting the SRP-X500P to a Computer About This Manual3 4 RS-232C indicator Communication FormatCommunication Protocol Communication Packet Format Handshake Codes1 AV/RGB Input Select 0x43 0x53 0x45 0x4C ‘CSEL’ Basic Control CommandsReturn packet format Input Fader 0x43 0x50 0x4D 0x35 ‘CPM5’Fader 1st-6th byte Input Fader Request 0x52 0x50 0x4D 0x35 ‘RPM5’Output Fader 0x43 0x50 0x4D 0x40 ‘CPM@’ Output Fader Request 0x52 0x50 0x4D 0x40 ‘RPM@’Fader 1st-8th byte Remote 1-6 Level 0x43 0x4C 0x56 0x4C ‘CLVL’ Channel 1st byteRemote Level 2nd byte Master Volume UP 0x43 0x4C 0x56 0x2B ‘CLV+’ Master Volume Level 1st byteRemote 1-6 Level 2nd-7th byte Master Volume Stop 0x43 0x4C 0x56 0x53 ‘CLVS’ Master Volume Down 0x43 0x4C 0x56 0x2D ‘CLV-’Muting 2nd byte Muting 0x43 0x4D 0x55 0x54 ‘CMUT’Muting Parameter Request 0x52 0x4D 0x55 0x54 ‘RMUT’ Input Muting 1st byteSpeaker Output Muting 2nd byte Master Muting 4th byte Line Output Muting 3rd byteRemote Muting 5th byte MasterProjector Control Request 1st byte Projector ON/STANDBY 0x43 0x50 0x4A 0x50 ‘CPJP’ Scene Recall 0x43 0x52 0x43 0x4C ‘CRCL’ Projector ON/STANDBY Indicator 1st byte Scene Recall Request 1st byte Scene Recall RequestScene No st byte Scene Recall Parameter Request 0x52 0x52 0x43 0x4C ‘RRCL’Status Acquisition Commands Index Request 0x52 0x50 0x4D 0x44 ‘RPMD’Index Level Meter Parameter Request 0x52 0x4D 0x54 0x52 ‘RMTR’ Level Meter 1st-16th byte To acquire status of single item To acquire the status of all items Parameters Input Volume 3rd-8th byte Master Volume Level 9th byteRemote 1-6 Level 10th-15th byte Input Level 16th-21st byte Output Level 22nd-29th byteInput Muting 30th byte Speaker Output Muting Output Muting 31st and 32nd byteLine Output Muting Master Muting 33rd byteWL Indicator 37th byte RF/AF Indicator 36th byte+48V Switch 38th byte MIC 1-4 Trim 39th-42nd byteREF Indicator 49th byte Line Trim 43rd byteAV/RGB Trim 44th-48th byte FR Setup Status 54th and 55th byte Setup ChannelFR 50th-53rd byte AV/RGB Input Select 56th byte Setup StatusSpeaker Output Level 57th, 58th byte Speaker Output CH1/2 LevelClip Indicator 77th byte IR Output Mode Indicator 59th byteLevel Meter 60th-75th byte Protection 76th byteTemperature Temperature 78th and 79th byteProjector ON/STANDBY Indicator 80th byte EMG Muting 83rd byteParallel Input 85th-94th byte Scene No th byteLevel Parallel Output 95th and 96th byteOutput Master Volume Control 98th byteFAN Motor 97th byte OUT6 OUT5 OUT4 OUT3 OUT2AGC Gain Control Gain Reduction 99th-108th byteCompressor Gain Reduction Information SETUPDATE2005/01/23 Maintenance Information CommandsInformation Request 0x52 0x50 0x4D 0x45 ‘RPME’ InformationMaintenance Information Read Write Maintenance Information Read WriteMaintenance Information Read only Maintenance Information Read onlyVersion Request 0x52 0x56 0x45 0x52 ‘RVER’ VersionVersion Factory Preset 0x43 0x52 0x53 0x54 ‘CRST’