Sony SRP-X500P manual Scene No th byte, Parallel Input 85th-94th byte, Level

Page 35

SRP-X500P RS-232C Interface Manual

SCENE No. (84th byte)

Shows the scene number to be recalled.

The parameter and the scene number are shown in the following table.

SCENE No.

None

0x30 (‘0’)

1

0x31 (‘1’)

2

0x32 (‘2’)

3

0x33 (‘3’)

4

0x34 (‘4’)

5

0x35 (‘5’)

6

0x36 (‘6’)

7

0x37 (‘7’)

8

0x38 (‘8’)

PARALLEL INPUT (85th-94th byte)

The information on the input pins of the REMOTE PARALLEL connector is provided using 10 bytes of data in the order shown in the following table.

Byte

Parameter

1st

INPUT 1 LEVEL

2nd

INPUT 2 LEVEL

3rd

INPUT 3 LEVEL

4th

INPUT 4 LEVEL

5th

INPUT 5 LEVEL

6th

INPUT 6 LEVEL

7th

INPUT 7 LEVEL

8th

INPUT 8 LEVEL

9th

INPUT 9 LEVEL

10th

INPUT 10 LEVEL

LEVEL

Shows the voltage input to the input pins of the REMOTE PARALLEL connector (in dB units). The correspondence of the parameter with the level setting is the same as that of the LEVEL parameter of the REMOTE 1-6 LEVEL command (page 10).

PARALLEL OUTPUT (95th and 96th byte)

Shows the on/off status of the output pins of the REMOTE PARALLEL connector.

The information on the output pins of the REMOTE PARALLEL connector is provided using 2 bytes of data in the order shown in the following table.

Byte

Parameter

1st

OUTPUT 1-6

2nd

OUTPUT 7-10

Page 35/43

Image 35
Contents SRP-X500P Table of Contents 3 4 Connecting the SRP-X500P to a ComputerAbout This Manual Communication Protocol RS-232C indicatorCommunication Format Communication Packet Format Handshake Codes1 AV/RGB Input Select 0x43 0x53 0x45 0x4C ‘CSEL’ Basic Control CommandsReturn packet format Input Fader 0x43 0x50 0x4D 0x35 ‘CPM5’Fader 1st-6th byte Input Fader Request 0x52 0x50 0x4D 0x35 ‘RPM5’Fader 1st-8th byte Output Fader 0x43 0x50 0x4D 0x40 ‘CPM@’Output Fader Request 0x52 0x50 0x4D 0x40 ‘RPM@’ Remote Remote 1-6 Level 0x43 0x4C 0x56 0x4C ‘CLVL’Channel 1st byte Level 2nd byte Remote 1-6 Level 2nd-7th byte Master Volume UP 0x43 0x4C 0x56 0x2B ‘CLV+’Master Volume Level 1st byte Master Volume Stop 0x43 0x4C 0x56 0x53 ‘CLVS’ Master Volume Down 0x43 0x4C 0x56 0x2D ‘CLV-’Muting 2nd byte Muting 0x43 0x4D 0x55 0x54 ‘CMUT’Speaker Output Muting 2nd byte Muting Parameter Request 0x52 0x4D 0x55 0x54 ‘RMUT’Input Muting 1st byte Master Line Output Muting 3rd byteMaster Muting 4th byte Remote Muting 5th byteProjector Control Request 1st byte Projector ON/STANDBY 0x43 0x50 0x4A 0x50 ‘CPJP’Scene Recall Request Projector ON/STANDBY Indicator 1st byteScene Recall 0x43 0x52 0x43 0x4C ‘CRCL’ Scene Recall Request 1st byteScene No st byte Scene Recall Parameter Request 0x52 0x52 0x43 0x4C ‘RRCL’Index Status Acquisition CommandsIndex Request 0x52 0x50 0x4D 0x44 ‘RPMD’ Level Meter Parameter Request 0x52 0x4D 0x54 0x52 ‘RMTR’ Level Meter 1st-16th byte To acquire status of single item To acquire the status of all items Parameters Remote 1-6 Level 10th-15th byte Input Volume 3rd-8th byteMaster Volume Level 9th byte Input Muting 30th byte Input Level 16th-21st byteOutput Level 22nd-29th byte Master Muting 33rd byte Output Muting 31st and 32nd byteSpeaker Output Muting Line Output MutingMIC 1-4 Trim 39th-42nd byte RF/AF Indicator 36th byteWL Indicator 37th byte +48V Switch 38th byteAV/RGB Trim 44th-48th byte REF Indicator 49th byteLine Trim 43rd byte FR 50th-53rd byte FR Setup Status 54th and 55th byteSetup Channel Speaker Output CH1/2 Level Setup StatusAV/RGB Input Select 56th byte Speaker Output Level 57th, 58th byteProtection 76th byte IR Output Mode Indicator 59th byteClip Indicator 77th byte Level Meter 60th-75th byteEMG Muting 83rd byte Temperature 78th and 79th byteTemperature Projector ON/STANDBY Indicator 80th byteParallel Output 95th and 96th byte Scene No th byteParallel Input 85th-94th byte LevelOUT6 OUT5 OUT4 OUT3 OUT2 Master Volume Control 98th byteOutput FAN Motor 97th byteAGC Gain Control Gain Reduction 99th-108th byteCompressor Gain Reduction Information Maintenance Information CommandsInformation SETUPDATE2005/01/23 Information Request 0x52 0x50 0x4D 0x45 ‘RPME’Maintenance Information Read Write Maintenance Information Read WriteMaintenance Information Read only Maintenance Information Read onlyVersion Version Request 0x52 0x56 0x45 0x52 ‘RVER’Version Factory Preset 0x43 0x52 0x53 0x54 ‘CRST’