2.3 Maintenance Information Commands
The following commands are provided to read and write the information on the
2.3.1 INFORMATION REQUEST : 0x52 0x50 0x4D 0x45 (‘RPME’)
This command is used to read information from the
The parameter that is shown for this command are the contents entered in the INFORMATION input section in the PANEL VIEW screen of the
Packet format
0x52 0x50 0x4D 0x45 0x0D
Return packet format
When the
0x41 “parameter” 0x0D
♦Parameter
The parameter consists of 128 bytes of data in the order shown in the following table.
Byte | Parameter |
INFORMATION |
•INFORMATION
The information is shown as 128 bytes of ASCII code.
If information is less than 128 bytes, space characters (0x20) are used as
Example
When the following information is indicated:
INFORMATION : SETUP□DATE□2005/01/23
0x41 0x53 0x45 0x54 0x55 0x50 0x20 0x44 0x41 0x54 0x45 0x20 0x32 0x30 0x30 0x35 0x2F 0x30 0x31 0x2F 0x32 0x33 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x0D
(‘A S E T U P□ D A T E□ 2 0 0 5 / 0 1 / 2 3 □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □
□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □
□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □
□□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ CR’) “□” indicates a space.
Page 39/43