Revolabs 03-HDEXECJP & 03-HDEXEC4JP, 03-HDEXECEU Using the Rear Panel Configuration DIP Switches

Page 11

Using the Rear Panel Configuration DIP Switches

off

on

1 2 3 4 5 6 7 8

1 – Operation Mode - Primary (off)/Secondary (on)

Used when connecting several base stations together for operation in the same area. One system must be set to ‗Primary‘, and all others must be set to ‗Secondary‘.

2 - future use

3 - future use

4 – Audio Output Level - Line (off)/Mic (on)

This controls the output audio level on all audio output connectors. Line level audio out (default) refers to an output signal voltage of ~0 dBu, and a Mic Level output signal level is ~-40 dBu.

5 - future use

6 - future use

7 - future use

8 - future use

Using the Revolabs HD Control Panel Software

A software program with graphical user interface is available for accessing control settings and real- time status of Revolabs Executive HD Microphone Systems. A detailed description of how to use this tool is described below.

1.Download the Revolabs HD Control Panel software from www.revolabs.com/downloads and install onto a PC running Windows 2000, NT, Vista or 7.

2.Connect the PC to the same network as the Base Station via either an Ethernet Crossover Cable, or network switch.

3.If no DHCP server is present, set the fixed IP on the PC to a similar IP address as the one displayed on the Base Station front panel display by changing the last bank of numbers in the IP address. (192.169.1.xxx)

4.Launch the Revolabs HD Control Panel program.

5.Select ‗Scan Network‘ from the ‗System‘ menu or hit the F5 key, and the HD Control Panel will automatically find and display any Revolabs Executive HD base stations visible on the network (the program cannot see through firewalls, etc.).

6.Select the devices needing to be configured and click ‗OK‘

Revolabs HD Gold Control Panel

Each Revolabs Executive HD Base Station comes standard with the HD Control Panel, which includes a limited group of controls and features. The Revolabs HD Gold Control Panel requires a 16 digit ‗unlock code‘ to access the additional features and functionality for each Executive HD Base Station. The HD System MAC address shown on the front LED panel of the Base Station is required to receive the unlock code. Each unlock code is tied directly to a specific MAC address and therefore, a specific system. The HD Gold Control Panel unlock code is available by purchasing a Revolabs Service Plan at the time of the system purchase, or may be purchased separately for each

- 11 -

Image 11
Contents Revolabs Executive HD Page Contents FCC Notice to Users Safety and General InformationStandards to which Conformity is declared System Components IntroductionInstalling the Revolabs Executive HD Base Station Controls and Connections Revolabs Executive HD Audio Connections Configuring the Executive Hdtm Base StationUsing Multiple Revolabs Executive Hdtm Systems Together Primary DIP#1 -off Secondary DIP#1 -on Wire BUS cable Revolabs HD Gold Control Panel Using the Rear Panel Configuration DIP SwitchesUsing the Revolabs HD Control Panel Software System Scan Network Configuration SettingsFile Record Events System Set Box Name System Set Telnet PasswordSystem Set IP Configuration Tools Express Pair System Enable GoldFirmware Update Firmware Config External Control ProcessorConfig Transmit Power Config Audio ModeConfig Redundancy Config Power ScalingStatus Monitoring Config Lock Front PanelConfig Audio Zone Monitor Microphone Version Monitor Microphone BatteryMonitor Microphone Type Monitor Versions Using the Serial Control Processor RS-232 or IPMonitor DIP Switches Using the Executive HD Base Station with a Control SystemString Table Serial Command & Return StringsPage ClearOne Converge & XAP Using the Executive HD Base Station with a DSPChannel # ExamplesMUTE4 Biamp Audia & NexiaPolycom SoundStructure Using the Base Station Front Panel Display Revolabs HD Microphones and HD Microphone Adapters Using the HD Wearable Wireless MicrophonesAdjusting the Volume on the Wearable Microphone Earpiece Pattern 360 ºPickup Acoustic Cover protects microphone element non-removable Using the HD XLR Microphone Wireless Adapter Using the HD Wireless Adapter for Countryman Microphone Pairing Wireless Microphones to Base Station Revolabs Executive HD Charger Base Updating the Executive HD Base Station & Microphones Power ModuleUpdating the Revolabs Hdtm Firmware Charging the Microphone BatteriesPage Green Revolabs Executive HD Indicator LEDsWarranty Dimensions, L, W, H and Weight SpecificationsMaximum Audio Channels Charger Bays Power Cord ReceptacleLED indicator Index